Table Of Contents
Cisco MDS 9000 Family Release Notes
for Cisco MDS SAN-OS Release 3.1(2)Determining the Software Version
Selecting the Correct Software Image for an MDS 9100 Series Switch
Selecting the Correct Software Image for an MDS 9500 Series Switch
Migrating from Supervisor-1 Modules to Supervisor-2 Modules
Configuring Generation 2 Switching Modules
Upgrading Your Cisco MDS SAN-OS Software Image
Performing a Nondisruptive Software Upgrade on Generation 1 Modules
Upgrading Your Version of Cisco Fabric Manager
Reconfiguring SSM Ports Before Upgrading to SAN-OS Release 3.1(2)
Upgrading the SSI Image on Your SSM
Upgrading a Switch with Insufficient Space for Two Images on the Bootflash
Upgrading a Cisco MDS 9124 Switch
Performing a Disruptive Upgrade on a Single Supervisor MDS Family Switch
Downgrading Your Cisco MDS SAN-OS Software Image
General Downgrading Guidelines
Downgrading the SSI Image on Your SSM
New Features in Cisco MDS SAN-OS Release 3.1(2)
Support for Cisco Fabric Switch for HP c-Class BladeSystem
Support for Cisco Fabric Switch for IBM BladeCenter
FCS Discovery of Virtual Devices
Compact Flash Report in Cisco Fabric Manager
Fabric Manager New Login Procedure
Virtual Router Redundancy Protocol (VRRP) Interfaces
QoS on an MDS 48-port Fibre Channel Module
Maximum Number of Zones Supported in Interop Mode 4
Configuring Default Settings for the Default Zone
Regulatory Compliance and Safety Information
Installation and Configuration Note
Cisco Product Security Overview
Reporting Security Problems in Cisco Products
Product Alerts and Field Notices
Obtaining Technical Assistance
Cisco Technical Support & Documentation Website
Definitions of Service Request Severity
Obtaining Additional Publications and Information
Cisco MDS 9000 Family Release Notes
for Cisco MDS SAN-OS Release 3.1(2)
Release Date: February 05, 2007
Text Part Number: OL-12208-02 S0
This document describes the caveats and limitations for switches in the Cisco MDS 9000 Family. Use this document in conjunction with documents listed in the "Related Documentation" section.
Note
Release notes are sometimes updated with new information on restrictions and caveats. Refer to the following website for the most recent version of the Cisco MDS 9000 Family Release Notes: http://www.cisco.com/en/US/products/hw/ps4159/ps4358/prod_release_notes_list.html
Table 1 shows the online change history for this document.
Table 1 Online History Change
Revision Date DescriptionA0
02/05/2007
Created release notes.
B0
02/07/2007
Added a "Maximum Number of Zones Supported in Interop Mode 4".
Revised the description of the Upgrade Path in Table 6 and the description of the Downgrade Path in Table 7.
Added the Limitation "Using SDV on a Cisco MDS 9124 Switch, on a Cisco Fabric Switch for HP c-Class BladeSystem, or on a Cisco Fabric Switch for IBM BladeCenter".
C0
02/14/2007
Added CSCsh69086 and CSCsh71985.
D0
02/27/2007
Added CSCsh66920.
Removed CSCsg19148.
E0
03/30/2007
Added DDTS CSCsg29630, CSCsh02602, CSCsh21262, CSCsh24256, CSCsh62126, CSCsh66010, CSCsh66920, CSCsh82676, CSCsh83200, CSCsh85505, CSCsh86629, CSCsh93540, CSCsh94906, and CSCsi24128.
Added the section "Performing a Disruptive Upgrade on a Single Supervisor MDS Family Switch".
Added the section "Configuring Default Settings for the Default Zone".
F0
04/05/2007
Revised the section "Upgrading a Cisco MDS 9124 Switch".
Added the section "Fabric Manager New Login Procedure".
G0
05/03/2007
Added DDTS CSCsg52197.
H0
05/15/2007
Removed the Interop Mode 4 Support Limitation.
I0
05/31/2007
Added DDTS CSCsh75149, CSCsi27133, CSCsi31860, CSCsi33540, CSCsi41668, and CSCsi52049.
J0
07/18/2007
Added DDTS CSCsj04224, CSCsj07363, and CSCsj19105.
Removed DDTS CSCei82909.
K0
08/24/2007
Added DDTS CSCsh95415.
L0
09/24/2007
Added DDTS CSCsi72048.
M0
09/27/2007
Added DDTS CSCeh35635, CSCsg49151, CSCsg62704, CSCsh05721, CSCsh63658, CSCsi49231, CSCsi56949, CSCsj13175, CSCsj29134, CSCsj52389, CSCsj64048, CSCsj65565, and CSCsj95379.
N0
10/24/2007
Changed the status of DDTS CSCsh31236 to Resolved.
Added a Note about Downgrading from Cisco SAN-OS 3.2(1) to the "Downgrading Your Cisco MDS SAN-OS Software Image" section.
P0
04/23/2008
Added DDTS CSCsk48149.
Q0
04/30/2008
Added DDTS CSCso63465.
R0
11/13/2008
Added the "Performing a Nondisruptive Software Upgrade on Generation 1 Modules" section.
S0
11/18/2008
Added DDTS CSCso72230.
Contents
This document includes the following sections:
•
Upgrading Your Cisco MDS SAN-OS Software Image
•
Downgrading Your Cisco MDS SAN-OS Software Image
•
New Features in Cisco MDS SAN-OS Release 3.1(2)
•
Cisco Product Security Overview
•
Obtaining Technical Assistance
•
Obtaining Additional Publications and Information
Introduction
The Cisco MDS 9000 Family of Multilayer Directors and Fabric Switches provides industry-leading availability, scalability, security, and management, allowing you to deploy high performance storage-area networks with lowest total cost of ownership. Layering a rich set of intelligent features onto a high performance, protocol agnostic switch fabric, the Cisco MDS 9000 Family addresses the stringent requirements of large data center storage environments: uncompromising high availability, security, scalability, ease of management, and seamless integration of new technologies.
The Cisco MDS 9000 Family SAN-OS is the underlying system software that powers the Cisco MDS 9500 Series, 9200 Series, and 9100 Series multilayer switches. The Cisco SAN-OS provides intelligent networking features, such as multiprotocol and multitransport integration, virtual SANs (VSANs), advanced security, sophisticated debug analysis tools, and unified SAN management.
Components Supported
Table 2 lists the SAN-OS software part number and hardware components supported by the Cisco MDS 9000 Family.
Note
To use the Cisco Storage Services Enabler package, Cisco MDS SAN-OS Release 1.3(5) or later must be installed on the MDS switch.
Table 2 Cisco MDS 9000 Family Supported Software and Hardware Components
Component Part Number Description Applicable ProductSoftware
M95S2K9-3.1.2
MDS 9500 Supervisor/Fabric-2, SAN-OS software.
MDS 9500 Series only
M95S1K9-3.1.2
MDS 9500 Supervisor/Fabric-I, SAN-OS software.
MDS 9500 Series only
M92S1K9-3.1.2
MDS 9216 Supervisor/Fabric-I, SAN-OS software.
MDS 9200 Series only
M91S2K9-3.1.2
MDS 9100 Supervisor/Fabric-2, SAN-OS software.
MDS 9100 Series only
M91S1K9-3.1.2
NDS 9100 Supervisor/Fabric-I, SAN-OS software
MDS 9100 Series only
License
M9500ENT1K9
Enterprise package.
MDS 9500 Series
M9200ENT1K9
Enterprise package.
MDS 9200 Series
M9100ENT1K9
Enterprise package.
MDS 9100 Series
M9500FIC1K9
Mainframe package.
MDS 9500 Series
M9200FIC1K9
Mainframe package.
MDS 9200 Series
M9100FIC1K9
Mainframe package.
MDS 9100 Series
M9500FMS1K9
Fabric Manager Server package.
MDS 9500 Series
M9200FMS1K9
Fabric Manager Server package.
MDS 9200 Series
M9100FMS1K9
Fabric Manager Server package.
MDS 9100 Series
M9500EXT1K9
SAN Extension over IP package for IPS-8 module.
MDS 9500 Series
M9200EXT1K9
SAN Extension over IP package for IPS-8 module.
MDS 9200 Series
M9500EXT14K9
SAN Extension over IP package for IPS-4 module.
MDS 9500 Series
M9200EXT14K9
SAN Extension over IP package for IPS-4 module.
MDS 9200 Series
M9500EXT12K9
SAN Extension over IP package for MPS 14+2 module.
MDS 9500 Series
M9200EXT12K9
SAN Extension over IP package for MPS 14+2 module.
MDS 9200 Series
M9500SSE1K9
Storage Services Enabler package.
MDS 9500 Series with SSM
M9200SSE1K9
Storage Services Enabler package.
MDS 9200 Series with SSM
M9124PL8-4G
On-Demand Ports Activation License
MDS 9124 Switch
HP-PL12-4G
On-Demand Ports Activation License
Cisco Fabric Switch for HP c-Class BladeSystem only
IBM-PL10-4G
On-Demand Ports Activation License
Cisco Fabric Switch for IBM BladeCenter only
Chassis
DS-C9513
MDS 9513 director (13-slot modular chassis with 11 slots for switching modules, and 2 slots reserved for Supervisor 2 modules only—SFPs1 sold separately).
MDS 9513 only
DS-C9509
MDS 9509 director, base configuration (9-slot modular chassis includes 7 slots for switching modules and 2 slots for supervisor modules—SFPs sold separately).
MDS 9509 only
DS-C9506
MDS 9506 director (6-slot modular chassis includes 4 slots for switching modules and 2 slots for supervisor modules—SFPs sold separately).
MDS 9506 only
DS-C9216-K9
MDS 9216 16-port semi-modular fabric switch (includes 16 1-Gbps/2-Gbps Fibre Channel ports, power supply, and expansion slot—SFPs sold separately).
MDS 9216 only
DS-C9216A-K9
MDS 9216A 16-port semi-modular fabric switch (includes 16 1-Gbps/2-Gbps Fibre Channel ports, power supply, and expansion slot—SFPs sold separately).
MDS 9216A only
DS-C9216i-K9
MDS 9216i 16-port semi-modular fabric switch (includes 14 1-Gbps/2-Gbps Fibre Channel ports, 2 Gigabit Ethernet ports, power supply, and expansion slot—SFPs sold separately).
MDS 9216i only
DS-C9140-K9
MDS 9140 fixed configuration (non-modular) fabric switch (includes 8 full rate ports and 32 host-optimized ports).
MDS 9140 only
DS-C9124-K9
MDS 9124 fixed configuration (non-modular) multilayer fabric switch (includes 8 enabled ports; an on-demand ports activation license can enable 8 additional ports, up to 24 ports).
MDS 9124 only
DS-C9120-K9
MDS 9120 fixed configuration, non-modular, fabric switch (includes 4 full rate ports and 16 host-optimized ports).
MDS 9120 only
DS-HP-FC-K9
Cisco Fabric Switch for HP c-Class BladeSystem (includes sixteen internal and eight external active ports and four 4-Gb SFPs installed, or eight internal and four external active ports and two 4-Gb SFPs installed).
Cisco Fabric Switch for HP c-Class BladeSystem only
DS-IBM-FC-K9
Cisco Fabric Switch for IBM BladeCenter (includes fourteen internal and six external ports)
Cisco Fabric Switch for IBM BladeCenter only
External crossbar module
DS-13SLT-FAB1
MDS 9513 crossbar fabric module.
MDS 9513 only
Supervisor modules
DS-X9530-SF2-K9
MDS 9500 Supervisor-2, module.
MDS 9500 Series only
DS-X9530-SF1-K9
MDS 9500 Supervisor/Fabric-I module.
Switching modules
DS-X9016
MDS 9000 16-port 1-Gbps/2-Gbps Fibre Channel module (SFPs sold separately).
MDS 9500 Series and 9200 Series
DS-X9032
MDS 9000 32-port 1-Gbps/2-Gbps Fibre Channel module (SFPs sold separately).
DS-X9112
MDS 9000 12-port 4-Gbps Fibre Channel module (SFPs sold separately).
MDS 9500 Series and 9200 Series, except for the MDS 9216
DS-X9124
MDS 9000 24-port 4-Gbps Fibre Channel module (SFPs sold separately).
MDS 9500 Series and 9200 Series, except for the MDS 9216
DS-X9148
MDS 9000 48-port 4-Gbps Fibre Channel module (SFPs sold separately).
MDS 9500 Series and 9200 Series, except for the MDS 9216
DS-X9704
MDS 9000 4-port 10-Gbps Fibre Channel module (SFPs sold separately)
MDS 9500 Series and 9200 Series, except for the MDS 9216
Services modules
DS-X9308-SMIP
8-port Gigabit Ethernet IP Storage services module.
MDS 9500 Series and 9200 Series
DS-X9304-SMIP
4-port Gigabit Ethernet IP Storage services module.
DS-X9032-SSM
MDS 9000 32-port 1-Gbps/2-Gbps Fibre Channel Storage Services Module (SSM).
DS-X9302-14K9
14-port Fibre Channel/2-port Gigabit Ethernet Multiprotocol Services (MPS-14/2) module.
Optics
DS-X2-FC10G-SR
X2/SC optics, 10-Gbps Fibre Channel for Short Reach.
MDS 9500 Series and 9200 Series, except for the MDS 9216
DS-X2-FC10G-LR
X2/SC optics, 10-Gbps Fibre Channel for Long Reach.
DS-X2-FC10G-ER
X2/SC optics, 10-Gbps Fibre Channel for Extended Reach (40 km).
LC-type fiber-optic SFP
DS-SFP-FC-2G-SW
2-Gbps/1-Gbps Fibre Channel—short wavelength SFP.
MDS 9000 Family
DS-SFP-FC-2G-LW
2-Gbps/1-Gbps Fibre Channel—long wavelength SFP.
DS-SFP-FCGE-SW
1-Gbps Ethernet and 1-Gbps/2-Gbps Fibre Channel—short wavelength SFP.
DS-SFP-FCGE-LW
1-Gbps Ethernet and 1-Gbps/2-Gbps Fibre Channel—long wavelength SFP.
DS-SFP-GE-T
1-Gbps Ethernet SFP.
DS-SFP-FC4G-SW
4-Gbps/2-Gbps/1-Gbps Fibre Channel—short wavelength SFP for DS-X91xx switching modules.
MDS 9500 Series and 9200 Series, except for the MDS 9216
DS-SFP-FC4G-MR
4-Gbps/2-Gbps/1-Gbps Fibre Channel—long wavelength SFP for DS-X91xx switching modules only. Supports distances up to 4 km.
DS-SFP-FC4G-LW
4-Gbps/2-Gbps/1-Gbps Fibre Channel—long wavelength SFP for DS-X91xx switching modules only. Supports distances up to 10 km.
CWDM2
DS-CWDM-xxxx
Gigabit Ethernet and 1-Gbps/2-Gbps Fibre Channel SFP LC interface xxxx nm, where xxxx = 1470, 1490, 1510, 1530, 1550, 1570, 1590, or 1610 nm.
MDS 9000 Family
DS-CWDM-MUX-4
Add/drop multiplexer for four CWDM wavelengths.
DS-CWDM-MUX-8
Add/drop multiplexer for eight CWDM wavelengths.
DS-CWDMCHASSIS
Two slot chassis for CWDM add/drop multiplexers.
Power supplies
DS-CAC-6000W
6000-W AC power supply.
MDS 9513 only
DS-CAC-2500W
2500-W AC power supply.
MDS 9509 only
DS-CDC-2500W
2500-W DC power supply.
DS-CAC-3000W
3000-W AC power supply.
DS-CAC-4000W-US
4000-W AC power supply for US (cable attached).
DS-CAC-4000W-INT
4000-W AC power supply international (cable attached).
DS-CAC-1900W
1900-W AC power supply.
MDS 9506 only
DS-CDC-1900W
1900-W DC power supply.
DS-CAC-845W
845-W AC power supply.
MDS 9200 Series only
DS-CAC-300W
300-W3 AC power supply.
MDS 9100 Series only
CompactFlash
MEM-MDS-FLD512M
MDS 9500 supervisor CompactFlash disk, 512 MB.
MDS 9500 Series only
Port analyzer adapter
DS-PAA-2, DS-PAA
A standalone Fibre Channel-to-Ethernet adapter that allows for simple, transparent analysis of Fibre Channel traffic in a switched fabric.
MDS 9000 Family
CD-ROM
M90FM-CD-212=
MDS 9000 Management Software and Documentation CD-ROM, spare.
MDS 9000 Family
1 SFP = small form-factor pluggable
2 CWDM = coarse wavelength division multiplexing
3 W = Watt
Software Download Process
Use the software download procedure to upgrade to a later version, or downgrade to an earlier version, of an operating system. This section describes the software download process for the Cisco MDS SAN-OS and includes the following topics:
•
Determining the Software Version
•
Selecting the Correct Software Image for an MDS 9500 Series Switch
•
Migrating from Supervisor-1 Modules to Supervisor-2 Modules
•
Configuring Generation 2 Switching Modules
Determining the Software Version
To determine the version of Cisco MDS SAN-OS software currently running on a Cisco MDS 9000 Family switch using the CLI, log in to the switch and enter the show version EXEC command.
To determine the version of Cisco MDS SAN-OS software currently running on a Cisco MDS 9000 Family switch using the Fabric Manager, view the Switches tab in the Information pane, locate the switch using the IP address, logical name, or WWN, and check its version in the Release column.
Note
We strongly recommend that you use the latest available software release supported by your vendor for all Cisco MDS 9000 Family products.
Downloading Software
The Cisco MDS SAN-OS software is designed for mission-critical high availability environments. To realize the benefits of nondisruptive upgrades on the Cisco MDS 9500 Directors, we highly recommend that you install dual supervisor modules.
To download the latest Cisco MDS SAN-OS software, access the Software Center at this URL:
http://www.cisco.com/public/sw-center
See the following sections in this release note for details on how you can nondisruptively upgrade your Cisco MDS 9000 switch. Issuing the install all command from the CLI, or using Fabric Manager to perform the downgrade, enables the compatibility check. The check indicates if the upgrade can happen nondisruptively or disruptively depending on the current configuration of your switch and the reason.
Compatibility check is done:Module bootable Impact Install-type Reason------ -------- -------------- ------------ ------1 yes non-disruptive rolling2 yes disruptive rolling Hitless upgrade is not supported3 yes disruptive rolling Hitless upgrade is not supported4 yes non-disruptive rolling5 yes non-disruptive reset6 yes non-disruptive resetAt a minimum, you need to disable the default device alias distribution feature using the no device-alias distribute command in global configuration mode. The show incompatibility system bootflash:1.3(x)_filename command determines which additional features need to be disabled.
Note
Refer to the "Determining Software Compatibility" section of the Cisco MDS 9000 Family CLI Configuration Guide for more details.
Note
If you would like to request a copy of the source code under the terms of either GPL or LGPL, please send an e-mail to mds-software-disclosure@cisco.com.
Selecting the Correct Software Image for an MDS 9100 Series Switch
The system and kickstart image that you use for an MDS 9100 series switch depends on which switch you use, as shown in Table 3.
Selecting the Correct Software Image for an MDS 9500 Series Switch
The system and kickstart image that you use for an MDS 9500 Series switch depends on whether the switch is based on a Supervisor-1 module or a Supervisor-2 module, as shown in Table 4.
Use the show module command to display the type of supervisor module in the switch.
For a Supervisor-1 module, the output might look like this:
switch# show moduleMod Ports Module-Type Model Status--- ----- -------------------------------- ------------------ ------------......5 0 Supervisor/Fabric-1 DS-X9530-SF1-K9 active*6 0 Supervisor/Fabric-1 DS-X9530-SF1-K9 ha-standbyFor a Supervisor-2 module, the output might look like this:
switch# show moduleMod Ports Module-Type Model Status--- ----- -------------------------------- ------------------ ------------......7 0 Supervisor/Fabric-2 DS-X9530-SF2-K9 active *8 0 Supervisor/Fabric-2 DS-X9530-SF2-K9 ha-standbyMigrating from Supervisor-1 Modules to Supervisor-2 Modules
As of Cisco MDS SAN-OS Release 3.0(1), the Cisco MDS 9509 and 9506 Directors support both Supervisor-1 and Supervisor-2 modules. Supervisor-1 and Supervisor-2 modules cannot be installed in the same switch, except during migration. Both the active and standby supervisor modules must be of the same type, either Supervisor-1 or Supervisor-2 modules. For Cisco MDS 9513 Directors, both supervisor modules must be Supervisor-2 modules.
CautionMigrating your supervisor modules is a disruptive operation.
Note
Migrating from Supervisor-2 modules to Supervisor-1 modules is not supported.
To migrate from a Supervisor-1 module to a Supervisor-2 module, refer to the step-by-step instructions in the Cisco MDS 9000 Family CLI Configuration Guide.
Configuring Generation 2 Switching Modules
The Cisco MDS 9500 Multilayer Directors are designed to operate with any combination of Cisco MDS 9000 Generation 1 and Generation 2 modules. However, there are limitations to consider when combining the various modules and supervisors in the Cisco MDS 9500 Series platform chassis. The references listed in this section provide specific information about configurations that combine different modules and supervisors.
For information on configuring Generation 2 switching modules, refer to:
http://www.cisco.com/en/US/products/ps5989/products_configuration_guide_chapter09186a0080664c6b.html
For information on port index availability, refer to:
http://www.cisco.com/en/US/products/ps5990/products_installation_guide_chapter09186a0080419599.html
For information on Cisco MDS 9000 hardware and software compatibility, refer to:
http://www.cisco.com/en/US/products/ps5989/products_device_support_table09186a00805037ee.html
Upgrading Your Cisco MDS SAN-OS Software Image
This section lists the guidelines recommended for upgrading your Cisco MDS SAN-OS software image and contains the following sections:
•
Performing a Nondisruptive Software Upgrade on Generation 1 Modules
•
Upgrading Your Version of Cisco Fabric Manager
•
Reconfiguring SSM Ports Before Upgrading to SAN-OS Release 3.1(2)
•
Upgrading the SSI Image on Your SSM
•
Upgrading a Switch with Insufficient Space for Two Images on the Bootflash
•
Upgrading a Cisco MDS 9124 Switch
•
Performing a Disruptive Upgrade on a Single Supervisor MDS Family Switch
CautionBefore upgrading your Cisco MDS SAN-OS software image, you must run the Compact Flash Report utility described in the "Compact Flash Report in Cisco Fabric Manager" section. This reporting feature automatically scans your switch fabric and reports the status of Compact Flash on certain switch modules. To run this utility prior to upgrading your Cisco SAN-OS software image, upgrade Cisco Fabric Manager as described in the "Upgrading Your Version of Cisco Fabric Manager" section.
For instructions on how to scan your switch fabric and display the status of Compact Flash using CLI commands, refer to the Cisco MDS 9000 Family CLI Configuration Guide.
Performing a Nondisruptive Software Upgrade on Generation 1 Modules
Generation 1 modules may reload during a nondisruptive SAN-OS software upgrade because of the Compact Flash being unable to partition for the new code. If that happens, the installer aborts and reloads the module.
This issue affects the following modules:
•
DS-X9016, 16-port 1-Gbps/2-Gbps Fibre Channel module
•
DS-X9032, 32-port 1-Gbps/2-Gbps Fibre Channel module
•
DS-X9032-SSM, 32-port 1-Gbps/2-Gbps Fibre Channel Storage Services Module (SSM)
•
DS-X9302-14K9, 14-port Fibre Channel/2-port Gigabit Ethernet Multiprotocol Services (MPS-14/2) module
This issue might be seen during an upgrade from Cisco SAN-OS Release 3.0(x), 3.1(x) or 3.2(x). It has been addressed for upgrades from SAN-OS Release 3.3(1) or higher. Therefore, you will not be impacted by this issue if you are running SAN-OS Release 3.3(1) when you upgrade to a higher SAN-OS release.
When this problem occurs, the module will automatically reload and may cause the Install All to stop, which will cause the upgrade to be unsuccessful. Error messages similar to the following may be displayed:
Install has failed. Return code 0x40930020 (Non-disruptive upgrade of a module failed).Please identify the cause of the failure, and try 'install all' again.Module 2: Non-disruptive upgrading.-- FAIL. Return code 0x40690009 (Error in downloading image for image upgrade).To avoid this kind of unplanned disruption, follow the methods for identifying and correcting this issue described in Cisco Field Notice 63099, before proceeding with the SAN-OS upgrade. This Field notice can be found under the Support, Products page for Cisco MDS9500 Series Multilayer Directors selection.
The caveat associated with this issue is CSCsm62295.
Upgrading Your Version of Cisco Fabric Manager
To upgrade your version of Cisco Fabric Manager, or install Cisco Fabric Manager for the first time, follow these steps:
Step 1
Download m9000-fm-3.1.2.jar from the Software Center on Cisco.com (http://www.cisco.com/pcgi-bin/tablebuild.pl/mds-fm). You must have a CCO account to access the files on Software Center.
Note
As of Cisco MDS SAN-OS Release 3.1, Cisco Fabric Manager requires Java 1.5.
Step 2
Launch the Fabric Manager installation program by doing one of the following:
a.
Navigate to the folder where you have downloaded the file and double-click it.
b.
Open the file using Internet Explorer.
c.
Enter java -jar m9000-fm-3.1.2.jar on the Windows or UNIX command line.
Step 3
Select an installation folder for Fabric Manager on your workstation. The default location is C:\Program Files\Cisco Systems\MDS 9000 for Windows. On a Solaris or Linux machine, the installation path name is /usr/local/cisco_mds9000 or $HOME/cisco_mds9000, depending on the permissions of the user performing the installation.
Note
The Fabric Manager Server and the Fabric Manager Client must be able to communicate with each other at all times. They can be installed on different workstations or the same workstation.
Step 4
Check the Don't install and run FM Server check box if you are installing just the Fabric Manager Client on a remote workstation.
Note
For other methods and details on upgrading, downgrading, and uninstalling Cisco Fabric Manager, refer to the Cisco MDS 9000 Family Fabric Manager Configuration Guide and the Cisco MDS 9000 Fabric Manager Quick Configuration Guide.
Step 5
Click Finish to complete the Cisco Fabric Manager installation.
General Upgrading Guidelines
Use the following guidelines when upgrading to Cisco MDS SAN-OS Release 3.1(2):
•
Install and configure dual supervisor modules.
•
Issue the show install all impact upgrade-image CLI command to determine if your upgrade will be nondisruptive.
•
Follow the recommended guidelines for upgrading a Cisco MDS 9124 Switch as described in "Upgrading a Cisco MDS 9124 Switch" section.
•
Follow the guidelines for upgrading a single supervisor switch as described in "Performing a Disruptive Upgrade on a Single Supervisor MDS Family Switch" section.
•
Be aware that some features impact whether an upgrade is disruptive or nondisruptive:
–
Fibre Channel Ports: Traffic on Fibre Channel ports can be nondisruptively upgraded. See Table 5 for the nondisruptive upgrade path for all SAN-OS releases.
–
SSM: Intelligent services traffic on the SSM, such as SANTap, NASB, and FC write acceleration, is disrupted during an upgrade. SSM Fibre Channel traffic is not.
–
Gigabit Ethernet Ports: Traffic on Gigabit Ethernet ports is disrupted during an upgrade or downgrade. This includes IPS modules and the Gigabit Ethernet ports on the MPS-14/2 module. Those nodes that are members of VSANs traversing an FCIP ISL are impacted, and a fabric reconfiguration occurs. iSCSI initiators connected to the Gigabit Ethernet ports lose connectivity to iSCSI targets while the upgrade is in progress.
–
IVR: With IVR enabled, you must follow additional steps if you are upgrading from Cisco SAN-OS Release 2.1.(1a), 2.1(1b), or 2.1.(2a). See the "Upgrading with IVR Enabled" section for these instructions.
–
FICON: If you have FICON enabled, the upgrade path is different. See Table 6.
Use Table 5 to determine your nondisruptive upgrade path to Cisco SAN-OS Release 3.1(2). Find the image release number you are currently using in the Current column of the table and use the path recommended.
Note
The software upgrade information in Table 5 applies only to Fibre Channel switching traffic. Upgrading system software disrupts IP traffic and SSM intelligent services traffic.
Use Table 6 to determine your nondisruptive upgrade path to Cisco MDS SAN-OS Release 3.1(2). Find the image release number you are currently using in the Current Release with FICON Enabled column of the table and use the path recommended.
Note
Cisco MDS SAN-OS Release 3.1(2) is not FICON certified.
Upgrading with IVR Enabled
An Inter-Switch Link (ISL) flap resulting in fabric segmentation or a merge during or after an upgrade from Cisco MDS SAN-OS Release 2.0(x) to a later image where IVR is enabled might be disruptive. Some possible scenarios include the following:
•
FCIP connection flapping during the upgrade process resulting in fabric segmentation or merge.
•
ISL flap results in fabric segmentation or merge because of hardware issues or a software bug.
•
ISL port becomes part of PCP results in fabric segmentation or merge because of a port flap.
If this problem occurs, syslogs indicate a failure and the flapped ISL could remain in a down state because of a domain overlap.
This issue was resolved in Cisco SAN-OS Release 2.1(2b); therefore, you must upgrade to Release 2.1(2b) before upgrading to Release 3.1(2). An upgrade from Cisco SAN-OS Releases 2.1(1a), 2.1(1b), or 2.1(2a) to Release 2.1(2b) when IVR is enabled requires that you follow the procedure below, and then follow the upgrade guidelines listed in the "Upgrading Your Version of Cisco Fabric Manager" section. If you have VSANs in interop mode 2 or 3, you must issue an IVR refresh for those VSANs.
To upgrade from Cisco SAN-OS Releases 2.1(1a), 2.1(1b), or 2.1(2a) to Release 2.1(2b) for all other VSANs with IVR enabled, follow these steps:
Step 1
Configure static domains for all switches in all VSANs where IVR is enabled. Configure the static domain the same as the running domain so that there is no change in domain IDs. Make sure that all domains are unique across all of the IVR VSANs. We recommend this step as a best practice for IVR-non-NAT mode. Issue the fcdomain domain id static vsan vsan id command to configure the static domains.
Note
Complete Step 1 for all switches before moving to Step 2.
Step 2
Issue the no ivr virtual-fcdomain-add vsan-ranges vsan-range command to disable RDI mode on all IVR enabled switches. The range of values for a VSAN ID is 1 to 4093. This can cause traffic disruption.
Note
Complete Step 2 for all IVR enabled switches before moving to Step 3.
Step 3
Check the syslogs for any ISL that was isolated.
2005 Aug 31 21:52:04 switch %FCDOMAIN-2-EPORT_ISOLATED:%$VSAN 2005%$ Isolation of interfaceport-channel 52 (reason: unknown failure)2005 Aug 31 21:52:04 switch %FCDOMAIN-2-EPORT_ISOLATED: %$VSAN 2005%$Isolation of interface port-channel 51(reason: domain ID assignment failure)Step 4
Issue the following commands for the isolated switches in Step 3:
switch(config)# vsan databaseswitch(config-vsan-db)# vsan vsan-id suspendswitch(config-vsan-db)# no vsan vsan-id suspendStep 5
Issue the ivr refresh command to perform an IVR refresh on all the IVR enabled switches.
Step 6
Issue the copy running-config startup-config command to save the RDI mode in the startup configuration on all of the switches.
Step 7
Follow the normal upgrade guidelines for Release 2.1(2b). If you are adding new switches running Cisco MDS SAN-OS Release 2.1(2b) or later, upgrade all of your existing switches to Cisco SAN-OS Release 2.1(2b) as described in this workaround. Then follow the normal upgrade guidelines for Release 3.1(2).
Note
RDI mode should not be disabled for VSANs running in interop mode 2 or interop mode 3.
Reconfiguring SSM Ports Before Upgrading to SAN-OS Release 3.1(2)
Starting with Cisco MDS SAN-OS Release 3.0(1), the SSM front panel ports can no longer be configured in auto mode, which is the default for releases prior to Release 3.0(1).
Note
To avoid any traffic disruption, modify the configuration of the SSM ports as described below, before upgrading a SAN-OS software image prior to Release 3.1(2).
For more information on upgrading SAN-OS software, see the "Upgrading Your Cisco MDS SAN-OS Software Image" section.
If the configuration is not updated before the upgrade, the installation process for the new image will automatically convert all ports configured in auto mode to Fx mode. This change in mode might cause a disruption if the port is currently operating in E mode.
To upgrade the image on your SSM without any traffic disruption, follow these steps:
Step 1
Verify the operational mode for each port on the SSM using the show interface command:
switch# show interface fc 2/1 - 32fc2/1 is upHardware is Fibre Channel, SFP is short wave laser w/o OFC (SN)Port WWN is 20:4b:00:0d:ec:09:3c:00Admin port mode is auto <-------- shows port is configured in auto modesnmp traps are enabledPort mode is F, FCID is 0xef0300 <-------- shows current port operational mode is FPort vsan is 1Speed is 2 GbpsTransmit B2B Credit is 3Step 2
Change the configuration for the first port of the quad when the admin port mode is auto. (A quad is a group of four ports, supported by a data path processor (DPP). The groups are 1 to 4, 5 to 8, 9 to 12, and so on.) Do not leave the port mode set to auto.
a.
Set the port admin mode to E or Fx if the current operational port mode is E, TE, F or FL.
switch# config tswitch(config)# interface fc 2/1switch(config-if)# switchport mode fxb.
Set the port admin mode to E if the current operational port mode is E:
switch# config tswitch(config)# interface fc 2/5switch(config-if)# switchport mode eStep 3
Change the configuration for ports 2, 3, and 4 of the quad:
a.
Set the admin port mode to Fx if the admin port mode of these ports is E, TE, or auto.
switch# config tswitch(config)# interface fc 2/2switch(config-if)# switchport mode fxb.
If the first port in the port group has admin mode E or if the port is operational in E port mode, change the admin state of ports 2, 3, and 4 to shutdown.
switch# config tswitch(config)# interface fc 2/2switch(config-if)# shutdownswitch# copy running-config startup-config
Upgrading the SSI Image on Your SSM
Use the following guidelines to nondisruptively upgrade the SSI image on your SSM:
•
Install and configure dual supervisor modules.
•
SSM intelligent services traffic on SSM ports is disrupted during upgrades. Fibre Channel switching traffic is not disrupted under the following conditions:
–
Upgrade the SSI boot images on the SSMs on the switch to a release version supported by your Cisco SAN-OS release. Refer to the Cisco MDS SAN-OS Release Compatibility Matrix for Storage Service Interface Images.
–
All SSM applications are disabled. Use the show ssm provisioning CLI command to determine what applications are configured. Use the no ssm enable feature CLI command to disable these applications.
–
No SSM ports are in auto mode. See the "Reconfiguring SSM Ports Before Upgrading to SAN-OS Release 3.1(2)" section.
–
The EPLD version on the SSM is at 0x07 or higher. Use the show version module slot epld CLI command to determine your EPLD version. Refer to the Cisco MDS 9000 Family Release Notes for Cisco MDS 9000 EPLD Images to upgrade your EPLD image.
–
Refer to the Cisco MDS Storage Services Module Interoperability Support Matrix and the "Managing Modules" chapter in the Cisco MDS 9000 Family CLI Configuration Guide, Release 3.x, for information on upgrading your SSM.
CautionUpgrading from Cisco MDS SAN-OS Release 2.1(1b) or earlier to Release 2.1.2 or later can disrupt traffic on any SSM installed on your MDS switch
Upgrading a Switch with Insufficient Space for Two Images on the Bootflash
To upgrade the SAN-OS image on a Cisco MDS 9000 Family switch requires enough space on the internal CompactFlash (also referred to as bootflash) to accommodate both the old software image and the new software image.
As of Cisco MDS SAN-OS Release 3.1(1), on MDS switches with a 256-MB CompactFlash, it is possible in some scenarios that a user might be unable to fit two images on the bootflash. This lack of space on the bootflash might cause the upgrade process to fail because new images are always copied onto the bootflash during an upgrade.
The following MDS switches are affected by this issue:
•
MDS 9216 and MDS 9216i
•
MDS 9120 and MDS 9140
•
MDS 9500 Series switches with a Supervisor 1 module
To work around an image upgrade failure caused by a lack of space on the bootflash, follow these steps:
Step 1
Prior to installing the new image, copy the old (existing) system image file to an external server. You may need to reinstall this file later.
Step 2
Delete the old system image file from the bootflash by using either the Fabric Manager install utility or the CLI delete bootflash: command. The system image file does not contain the word "kickstart" in the filename.
switch# delete bootflash:m9200-ek9-mz.3.0.3.bin
Note
On MDS 9500 Series switches, you also need to delete the image file from the standby supervisor after deleting it from the active supervisor.
switch# delete bootflash://sup-standby/m9500-sf1ek9-mz.3.0.3.binStep 3
Start the image upgrade or installation process using the Fabric Manager install utility or the CLI install all command.
Step 4
If the new installation or upgrade fails while copying the image and you want to keep the old (existing) image, then copy the old image (that you saved to an external server in Step 1) to the bootflash using either Fabric Manager or the copy command.
Step 5
If the switch fails to boot, then follow the recovery procedure described in the "Troubleshooting Installs, Upgrades, and Reboots" section of the Cisco MDS 9000 Family Troubleshooting Guide, Release 3.x.
Upgrading a Cisco MDS 9124 Switch
If you are upgrading from Cisco MDS SAN-OS Release 3.1(1) to Cisco SAN-OS Release 3.1(2) on a Cisco MDS 9124 Switch, follow these guidelines:
•
During the upgrade, configuration is not allowed and the fabric is expected to be stable.
•
The Fabric Shortest Path First (FSPF) timers must be configured to the default value of 20 seconds; otherwise, the nondisruptive upgrade is blocked to ensure that the maximum down time for the control plane can be 80 seconds.
•
If there are any CFS commits in the fabric, the nondisruptive upgrade will fail.
•
If there is a zone server merge in progress in the fabric, the nondisruptive upgrade will fail.
•
If a service terminates the nondisruptive upgrade, the show install all failure-reason command can display the reason that the nondisruptive upgrade cannot proceed.
•
If there is not enough memory in the system to load the new images, the upgrade will be made disruptive due to insufficient resources and the user will be notified in the compatibility table.
Note
Before starting the upgrade, issue the no logging level all command. If you do not, the upgrade might fail because of many system log messages printing. This could result in the down time for control plane exceeding 80 seconds.
Note
If the management interface of the fabric switch is connected to a Layer 2 switch, we recommend that you enable PortFast on the interface of the switch to which the management interface is connected. By doing so, you avoid spanning-tree convergence time on the switch and ensure packets from the fabric switch are forwarded immediately during the nondisruptive upgrade.
Performing a Disruptive Upgrade on a Single Supervisor MDS Family Switch
Cisco MDS SAN-OS software upgrades are disruptive on the following single supervisor Cisco MDS Family switches:
•
MDS 9120 switch
•
MDS 9140 switch
•
MDS 9216i switch
If you are performing an upgrade on one of those switches, you should follow the nondisruptive upgrade path shown in Table 5, even though the upgrade is disruptive. Following the nondisruptive upgrade path ensures that the binary startup configuration remains intact.
If you do not follow the upgrade path, (for example, you upgrade directly from SAN-OS Release 2.1(2b) to SAN-OS Release 3.1(2b)), the binary startup configuration is deleted because it is not compatible with the new image, and the ASCII startup configuration file is applied when the switch comes up with the new upgraded image. When the ASCII startup configuration file is applied, there may be errors. Because of this, we recommend that you follow the nondisruptive upgrade path.
Downgrading Your Cisco MDS SAN-OS Software Image
This section lists the guidelines recommended for downgrading your Cisco MDS SAN-OS software image and contains the following sections:
•
General Downgrading Guidelines
•
Downgrading the SSI Image on Your SSM
General Downgrading Guidelines
Use the following guidelines to nondisruptively downgrade your Cisco MDS SAN-OS Release 3.1(2):
•
Install and configure dual supervisor modules.
•
Issue the system no acl-adjacency-sharing execute command to disable acl adjacency usage on Generation 2 and Generation 1 modules. If