Guest

Cisco Catalyst 6500 Series Switches

Catalyst 6500 Series DFC Memory Installation Note

Table Of Contents

Catalyst 6500 Series DFC Memory Installation Note

Contents

Safety Overview

Required Tools

Installation Guidelines

Verifying the DFC Memory

Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)

Removing the SODIMM

Installing the SODIMM

Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)

Related Documentation

Obtaining Documentation

Cisco.com

Ordering Documentation

Documentation Feedback

Obtaining Technical Assistance

Cisco Technical Support Website

Submitting a Service Request

Definitions of Service Request Severity

Obtaining Additional Publications and Information


Catalyst 6500 Series DFC Memory Installation Note


Product numbers:
MEM-DFC-128M=, MEM-DFC-256M=, MEM-DFC-512M= (for WS-F6K-DFC)
MEM-XCEF720-512M= (for WS-F6K-DFC3A, WS-F6700-DFC3A, WS-F6700-DFC3B)
MEM-XCEF720-1GB= (for WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL)

This publication provides procedures for installing memory on the following Catalyst 6500 series Distributed Forwarding Cards (DFCs):

WS-F6K-DFC

WS-F6K-DFC3A

WS-F6700-DFC3A

WS-F6700-DFC3B

WS-F6700-DFC3BXL


Note For the WS-F6700-DFC3A, WS-F6700-DFC3B, and WS-F6700-DFC3BXL, the memory module is located on the base WS-X67xx module, under the DFC3 daughtercard. You must remove the daughtercard from the module to upgrade the memory.


Contents

This publication contains these sections:

Safety Overview

Required Tools

Installation Guidelines

Verifying the DFC Memory

Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)

Removing the SODIMM

Installing the SODIMM

Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)

Related Documentation

Obtaining Documentation

Documentation Feedback

Obtaining Technical Assistance

Obtaining Additional Publications and Information

Safety Overview

Safety warnings appear throughout this publication in procedures that, if performed incorrectly, may harm you. A warning symbol precedes each warning statement.

Warning


IMPORTANT SAFETY INSTRUCTIONS

This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. Use the statement number provided at the end of each warning to locate its translation in the translated safety warnings that accompanied this device. Statement 1071

SAVE THESE INSTRUCTIONS



Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030



Warning Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. Statement 1034


Required Tools

These tools are required to upgrade the memory on the Catalyst 6500 series DFC:

3/16-inch flat-blade screwdriver for the captive installation screws on the module on which the DFC is installed

WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL only—Number 1 Phillips-head screwdriver for the screws and cap nuts that fasten the DFC3 to the WS-X67xx module

Antistatic mat or antistatic foam

Your own ESD-prevention equipment or the disposable grounding wrist strap included with all upgrade kits, field-replaceable units (FRUs), and spares


Caution Always use an ESD wrist strap when handling modules or coming into contact with internal components.

Installation Guidelines

Observe the following cautions when upgrading the memory on a DFC:


Caution Always use an ESD wrist strap when handling modules or coming into contact with internal components.

Caution During this procedure, wear grounding wrist straps to avoid ESD damage to the module. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself.

Caution SODIMMs are sensitive components that are susceptible to ESD damage. To prevent ESD damage, handle SODIMMs by the edges only; avoid touching the memory modules, pins, or traces (the metal fingers along the connector edge of the SODIMM).

Caution When inserting SODIMMs, use firm but not excessive pressure. If you damage a socket, you will have to return the DFC to the factory for repair.

Caution Use care not to damage the connectors on the module. If you damage a connector, it will be necessary to return the module to Cisco for repair.

Caution You must install screws in all available standoffs. The screws provide grounding between the DFC3 and the module. Failure to install all screws will invalidate the safety approvals and pose a risk of fire and electrical hazard.

Verifying the DFC Memory

Table 1 lists the default memory configurations and available upgrades.

Table 1 Memory Configurations

DFC version
Default Memory
Upgradeable Memory
Part Number

WS-F6K-DFC3

128 MB

256 MB
512 MB

MEM-DFC-256M=
MEM-DFC-512M=

WS-F6K-DFC3A

512 MB

No upgrade available

-

WS-F6700-DFC3A

256 MB

512 MB
1 GB

MEM-XCEF720-512M=
MEM-XCEF720-1GB=

WS-F6700-DFC3B

256 MB

512 MB
1 GB

MEM-XCEF720-512M=
MEM-XCEF720-1GB=

WS-F6700-DFC3BXL

1 GB

No upgrade available

-


To verify the memory configuration on the DFC, enter the remote command module mod show memory summary command, where mod is the module with an installed DFC. Add the processor and I/O totals to get the total memory for the DFC.

This example shows how to check the total memory on the DFC on a fabric-enabled module in slot 9:

Router# remote command module 9 show memory summary

Router-dfc9#
                Head    Total(b)     Used(b)     Free(b)   Lowest(b) Largest(b)
Processor   31C5BFC0   205144128   127792712    77351416    65520524 64818696
      I/O    E000000    33554440     5987288    27567152    27567152 27567100

...<output truncated>

Router#

The above example shows the total memory on the DFC is 256 MB.

Removing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)

For the WS-F6700-DFC3A, WS-F6700-DFC3B, and WS-F6700-DFC3BXL, the memory module is located on the base WS-X67xx module, under the DFC3. To upgrade the DFC3 memory, you must first remove the DFC3 from the module.

To remove a DFC3, follow these steps:


Warning Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. Statement 1034



Caution During this procedure, wear grounding wrist straps to avoid ESD damage to the module. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself.


Step 1 Remove the module from the Catalyst 6500 series switch. (Refer to the Catalyst 6500 Series Module Installation Guide for removal instructions.)

Step 2 Place the module on an antistatic mat or foam, with the front of the module facing toward you.

Step 3 Use a Phillips-head screwdriver to remove the securing screws and the two cap nuts. (See Figure 1.)

Figure 1 Removing the Securing Screws and Cap Nuts

Step 4 Partially install the cap nut, as shown in Figure 2, about 3 turns so that there is a space of about 1/8 inch (3.175 mm) between the bottom of the cap nut and the top of the DFC3. The cap nut acts as a stop when you unseat the connector so that the DFC3 does not move horizontally and cause damage to the module.

Figure 2 Partially Installing the Cap Nut

Step 5 With your left hand, lift slightly at the location shown in Figure 3. While lifting with your left hand, rock the DFC3 up and down with your right hand, no more than half an inch in either direction, to unseat the DFC3 from the module.

Figure 3 Unseat the DFC3 from the Module

Step 6 Remove the cap nut.

Step 7 Hold the DFC3 with both hands, and gently lift the DFC3 straight up from the module. (See Figure 4.)

Figure 4 Removing the DFC3 from the Module

Step 8 Place the removed DFC3 on an antistatic mat or antistatic foam pad.

Step 9 Proceed to the "Removing the SODIMM" section.


Removing the SODIMM


Caution During this procedure, wear grounding wrist straps to avoid ESD damage to the card. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself.

To remove the existing SODIMM, follow these steps:


Step 1 Make sure that you take the necessary precautions to prevent ESD damage.

Step 2 Remove the module with the DFC or DFC3A from the system. (Refer to the Catalyst 6500 Series Module Installation Guide for removal instructions.)

Step 3 Place the module on an antistatic mat or pad.

Step 4 Locate the SODIMM. (See Figure 5 for the WS-F6K-DFC, see Figure 6 for the WS-F6K-DFC3A, and see Figure 7 for the WS-X6700-DFC3A.)

Figure 5 Location of SODIMM on a WS-F6K-DFC

Figure 6 Location of SODIMM on a WS-F6K-DFC3A

Figure 7 Location of SODIMM on a WS-X67xx Module for the DFC3A, DFC3B, and DFC3BXL

Step 5 Release the spring clips from the SODIMM, and release the SODIMM from the socket. (See Figure 8.)

Figure 8 Releasing the SODIMM Spring Clips

Step 6 When both ends of the SODIMM are released from the socket, grasp the ends of the SODIMM with your thumb and forefinger, and pull the SODIMM completely out of the socket.


Caution SODIMMs are sensitive components that are susceptible to ESD damage. To prevent ESD damage, handle SODIMMs by the edges only; avoid touching the memory modules, pins, or traces (the metal fingers along the connector edge of the SODIMM). (See Figure 9.)

Step 7 Place the SODIMM in an antistatic container to protect it from ESD damage.


This completes the SODIMM removal procedure. Proceed to the "Installing the SODIMM" section to install the new SODIMM.

Installing the SODIMM


Caution SODIMMs are sensitive components that are susceptible to ESD damage. To prevent ESD damage, handle SODIMMs by the edges only; avoid touching the memory modules, pins, or traces (the metal fingers along the connector edge of the SODIMM). (See Figure 9.)

Figure 9 Handling a SODIMM

Follow these steps to install the new SODIMM:


Step 1 Remove a new SODIMM from the antistatic container.

Step 2 Hold the SODIMM with the component side up and with the connector edge (the metal fingers) away from you.

Step 3 Hold the sides of the SODIMM between your thumbs and forefingers. (See Figure 9.)

Step 4 Tilt the SODIMM to approximately the same angle as the socket, and insert the connector edge into the socket.


Caution When inserting SODIMMs, use firm but not excessive pressure. If you damage a socket, you will have to return the DFC to the factory for repair.

Step 5 Press the SODIMM down until it is secured by the spring clips. (See Figure 10.)

Figure 10 Installing the SODIMM

Step 6 When the SODIMM is installed, check the two alignment holes, and ensure that the spring retainer is visible. If it is not, the SODIMM is not seated properly. If any SODIMM appears misaligned, carefully remove it and reseat it in the socket. Push the SODIMM firmly back into the socket until the retainer springs snap into place.

Step 7 If you upgraded the memory on the WS-F6700-DFC3A, WS-F6700-DFC3B, or WS-F6700-DFC3BXL, you need to reinstall the DFC3. Proceed to the "Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)" section to install the DFC3.

Otherwise, reinstall the module. (Refer to the Catalyst 6500 Series Module Installation Guide for removal instructions.)


Installing the DFC3 (WS-F6700-DFC3A, WS-F6700-DFC3B, WS-F6700-DFC3BXL Only)

To install the DFC3 on a WS-X67xx module, follow these steps:


Caution During this procedure, wear grounding wrist straps to avoid ESD damage to the module. Do not directly touch the backplane with your hand or any metal tool, or you could shock yourself.


Step 1 Align the mounting holes on the DFC3 (see Figure 11) with the male standoffs on the module. (See Figure 12.) Make sure that the remaining mounting holes on the DFC3 are aligned with the remaining standoffs.

Figure 11 Mounting Holes on the DFC3

Figure 12 Male Standoff Locations on the WS-X67xx Module

Step 2 Ensure that the connectors on the DFC3 are aligned with the connectors on the module. Figure 13 shows the connectors on the underside of the DFC3.

Figure 13 DFC3A Connectors

Step 3 Apply pressure to the area shown in Figure 14 to seat the power connector.

Figure 14 Seating the Power Connector


Caution Use care not to damage the connectors on the module. If you damage a connector, it will be necessary to return the module to Cisco for repair.

Step 4 Apply pressure to the location shown in Figure 15 to fully seat the DFC3 on the module.

Figure 15 Seating the DFC3 on the Module

Step 5 Use a Phillips-head screwdriver to install the securing screws and the two cap nuts. (See Figure 16.)


Caution You must install screws in all available standoffs. The screws provide grounding between the DFC3 and the module. Failure to install all screws will invalidate the safety approvals and pose a risk of fire and electrical hazard.


Note You should visually verify that there are standoffs beneath the mounting holes before installing the securing screws.


Figure 16 Installing the Securing Screws and Cap Nuts

Step 6 Install the module in the Catalyst 6500 series switch. (Refer to the Catalyst 6500 Series Module Installation Guide for installation instructions.)


Related Documentation

These documents are available for the Catalyst 6500 series switches:

Regulatory Compliance and Safety Information for the Catalyst 6500 Series Switches

Catalyst 6500 Series Switch Installation Guide

Catalyst 6500 Series Switch Module Installation Guide

Catalyst 6500 Series Switch Software Configuration Guide

Catalyst 6500 Series Switch Command Reference

Catalyst 6500 Series Switch Cisco IOS Software Configuration Guide

Catalyst 6500 Series Switch Cisco IOS Command Reference

Catalyst 6500 Series DFC/DFC3A Installation Note

Catalyst 6500 Series DFC3A, DFC3B, and DFC3BXL Installation Note

Obtaining Documentation

Cisco documentation and additional literature are available on Cisco.com. Cisco also provides several ways to obtain technical assistance and other technical resources. These sections explain how to obtain technical information from Cisco Systems.

Cisco.com

You can access the most current Cisco documentation at this URL:

http://www.cisco.com/univercd/home/home.htm

You can access the Cisco website at this URL:

http://www.cisco.com

You can access international Cisco websites at this URL:

http://www.cisco.com/public/countries_languages.shtml

Ordering Documentation

You can find instructions for ordering documentation at this URL:

http://www.cisco.com/univercd/cc/td/doc/es_inpck/pdi.htm

You can order Cisco documentation in these ways:

Registered Cisco.com users (Cisco direct customers) can order Cisco product documentation from the Ordering tool:

http://www.cisco.com/en/US/partner/ordering/index.shtml

Nonregistered Cisco.com users can order documentation through a local account representative by calling Cisco Systems Corporate Headquarters (California, USA) at 408 526-7208 or, elsewhere in North America, by calling 800 553-NETS (6387).

Documentation Feedback

You can send comments about technical documentation to bug-doc@cisco.com.

You can submit comments by using the response card (if present) behind the front cover of your document or by writing to the following address:

Cisco Systems
Attn: Customer Document Ordering
170 West Tasman Drive
San Jose, CA 95134-9883

We appreciate your comments.

Obtaining Technical Assistance

For all customers, partners, resellers, and distributors who hold valid Cisco service contracts, Cisco Technical Support provides 24-hour-a-day, award-winning technical assistance. The Cisco Technical Support Website on Cisco.com features extensive online support resources. In addition, Cisco Technical Assistance Center (TAC) engineers provide telephone support. If you do not hold a valid Cisco service contract, contact your reseller.

Cisco Technical Support Website

The Cisco Technical Support Website provides online documents and tools for troubleshooting and resolving technical issues with Cisco products and technologies. The website is available 24 hours a day, 365 days a year at this URL:

http://www.cisco.com/techsupport

Access to all tools on the Cisco Technical Support Website requires a Cisco.com user ID and password. If you have a valid service contract but do not have a user ID or password, you can register at this URL:

http://tools.cisco.com/RPF/register/register.do

Submitting a Service Request

Using the online TAC Service Request Tool is the fastest way to open S3 and S4 service requests. (S3 and S4 service requests are those in which your network is minimally impaired or for which you require product information.) After you describe your situation, the TAC Service Request Tool automatically provides recommended solutions. If your issue is not resolved using the recommended resources, your service request will be assigned to a Cisco TAC engineer. The TAC Service Request Tool is located at this URL:

http://www.cisco.com/techsupport/servicerequest

For S1 or S2 service requests or if you do not have Internet access, contact the Cisco TAC by telephone. (S1 or S2 service requests are those in which your production network is down or severely degraded.) Cisco TAC engineers are assigned immediately to S1 and S2 service requests to help keep your business operations running smoothly.

To open a service request by telephone, use one of the following numbers:

Asia-Pacific: +61 2 8446 7411 (Australia: 1 800 805 227)
EMEA: +32 2 704 55 55
USA: 1 800 553 2447

For a complete list of Cisco TAC contacts, go to this URL:

http://www.cisco.com/techsupport/contacts

Definitions of Service Request Severity

To ensure that all service requests are reported in a standard format, Cisco has established severity definitions.

Severity 1 (S1)—Your network is "down," or there is a critical impact to your business operations. You and Cisco will commit all necessary resources around the clock to resolve the situation.

Severity 2 (S2)—Operation of an existing network is severely degraded, or significant aspects of your business operation are negatively affected by inadequate performance of Cisco products. You and Cisco will commit full-time resources during normal business hours to resolve the situation.

Severity 3 (S3)—Operational performance of your network is impaired, but most business operations remain functional. You and Cisco will commit resources during normal business hours to restore service to satisfactory levels.

Severity 4 (S4)—You require information or assistance with Cisco product capabilities, installation, or configuration. There is little or no effect on your business operations.

Obtaining Additional Publications and Information

Information about Cisco products, technologies, and network solutions is available from various online and printed sources.

Cisco Marketplace provides a variety of Cisco books, reference guides, and logo merchandise. Visit Cisco Marketplace, the company store, at this URL:

http://www.cisco.com/go/marketplace/

The Cisco Product Catalog describes the networking products offered by Cisco Systems, as well as ordering and customer support services. Access the Cisco Product Catalog at this URL:

http://cisco.com/univercd/cc/td/doc/pcat/

Cisco Press publishes a wide range of general networking, training and certification titles. Both new and experienced users will benefit from these publications. For current Cisco Press titles and other information, go to Cisco Press at this URL:

http://www.ciscopress.com

Packet magazine is the Cisco Systems technical user magazine for maximizing Internet and networking investments. Each quarter, Packet delivers coverage of the latest industry trends, technology breakthroughs, and Cisco products and solutions, as well as network deployment and troubleshooting tips, configuration examples, customer case studies, certification and training information, and links to scores of in-depth online resources. You can access Packet magazine at this URL:

http://www.cisco.com/packet

iQ Magazine is the quarterly publication from Cisco Systems designed to help growing companies learn how they can use technology to increase revenue, streamline their business, and expand services. The publication identifies the challenges facing these companies and the technologies to help solve them, using real-world case studies and business strategies to help readers make sound technology investment decisions. You can access iQ Magazine at this URL:

http://www.cisco.com/go/iqmagazine

Internet Protocol Journal is a quarterly journal published by Cisco Systems for engineering professionals involved in designing, developing, and operating public and private internets and intranets. You can access the Internet Protocol Journal at this URL:

http://www.cisco.com/ipj

World-class networking training is available from Cisco. You can view current offerings at this URL:

http://www.cisco.com/en/US/learning/index.html