Table Of Contents
Technical Specifications
MGX 8230 Enclosure, Power, and Performance Specifications
MGX 8230 Processor Switching Module Specifications
AUSM/B-8T1E1 Interface Characteristics
FRSM-2CT3 Specifications
FRSM-2CT3 Framer
FRSM-2CT3 Line Alarms
FRSM-2T3E3 Specifications
FRSM-2T3E3 T3 Line
T3 Framer Level
FRSM-2T3E3 E3 Line
E3 Framer Level
FRSM-2T3E3 Line Alarms
Statistics and Counter Specifications
FRSM-HS2 Specifications
Counters and Statistics for FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2
FRSM-8T1 Specification
FRSM-8E1 Specification
Circuit Emulation Service Module for T1 Operation
Circuit Emulation Service Module for E1 Operation
Physical and Electrical Characteristics for Cards
Electromagnetic Compatibility
Conformance
ATM UNI
SONET/SDH
Frame Relay
Circuit Emulations Service
Safety
Environmental
Technical Specifications
This appendix provides the technical specifications relevant to the MGX 8230, its processor and service modules, and the applications and services that it provides. It contains the following sections:
•
MGX 8230 Enclosure, Power, and Performance Specifications
•
MGX 8230 Processor Switching Module Specifications
•
AUSM/B-8T1E1 Interface Characteristics
•
FRSM-2CT3 Specifications
•
FRSM-2T3E3 Specifications
•
FRSM-HS2 Specifications
•
Counters and Statistics for FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2
•
FRSM-8T1 Specification
•
FRSM-8E1 Specification
•
Circuit Emulation Service Module for T1 Operation
•
Circuit Emulation Service Module for E1 Operation
•
Physical and Electrical Characteristics for Cards
•
Electromagnetic Compatibility
•
Conformance
MGX 8230 Enclosure, Power, and Performance Specifications
This section describes the physical characteristics and system power requirements for the
MGX 8230 feeder. The "MGX 8230 Processor Switching Module Specifications" section lists the dimensions, weight, and power consumption for each card. The appendix titled "Cabling Specifications" lists the AC power plugs for domestic and international use.
Table A-1 shows the MGX 8230 enclosure and electrical characteristics.
Table A-1 Enclosure and Electrical Characteristics
Item
|
Value
|
Card Slot Capacity
|
Supports combinations of full and single-height service modules. Two double-height slots reserved for PXMs. Up to 10 single-height slots for service modules or up to 5 double-height slots for service modules.
|
Enclosure Size, AC-powered system
DC-powered system
|
8 Rack Units high Height: 14.00 inches (35.56 cm). Width: 17.72 ins (45.01 cm). Depth: 23.5 ins (59.69 cm) (excluding cable management)
7 Rack Units high Height: 12.25 inches (63.50 cm). Width: 17.72 inches (45.01 cm). Depth: 23.5 inches (59.69 cm) (excluding cable management)
|
Shipping Weight for Populated Enclosure
|
Approximately 150 lbs.
|
Clearance Requirement
|
Minimum 30 inches front and rear; nominal 12-inch side clearance.
|
Power Input Voltage
|
AC system: Normal operating range is 100-240 VAC, 47 to 63 Hz. The maximum voltage range is 90-264 VAC. DC system: -42 to -56 VDC.
Each AC supply can provide up to 1200 Watts at -48 VDC.
|
Current Requirements, AC System
|
Configuration-dependent: use Network Design Tool for exact requirements.
|
Current Requirements, DC System
|
Configuration-dependent: use Network Design Tool for exact requirements. For general planning purposes: 25 Amps at nominal -48 VDC; 29 Amps at -42 VDC maximum.
|
Input AC Power Connector
|
IEC 320 C13 input connector. The Appendix titled "Cabling Specifications" lists the AC power cords for a variety of countries and regions.
|
AC Power Cable
|
Provided with 8 feet (2.3 m) of 3-conductor wire with plug.
|
AC Plug at Customer end
|
20 A NEMA L620, 3-prong plug (domestic U.S.) 13 A 250 Vac BS1363, 3-prong fused plug (UK, Ireland) CEE 7/7 (Continental Europe) AS3112 (Australia/New Zealand) CEI23-16/VII (Italy) 125V/15A North America
|
DC Input Connections
|
Three-position terminal block for 10 AWG wire (4 square millimeters).
|
Operating Environment
|
0×-40× C (32×-104× F) normal operation (50× C or 122× F up to 72 hours). Maximum 85% relative humidity.
|
Shock
|
Withstands 10 G, 10 ms at 1/2 sine wave.
|
Vibration
|
Withstands 1/4 G, 20-500 Hz.
|
Heat Transfer to Environment
|
AC-powered: 4,800 BTUs. DC-powered: 4,100 BTUs.
|
MGX 8230 Performance
|
Cell bus bandwidth
Slots 3 to 5, 10 to 12:
Slots 6 to 7, 13 to 14
|
~160 Mbps per slot, single speed ~320 Mbps per slot, double speed
~160 Mbps per two slots, single speed ~320 Mbps per two slots, double speed
|
Alarm and error handling
|
Same as MGX 8850 and IGX 8400 series switches
|
MGX 8230 Processor Switching Module Specifications
This section contains general specifications for the MGX 8230 Processor Switch Module
(MGX 8230-PXM). The information in Table A-2 includes information for the two types of back cards—the PXM-UI user interface for the switch and the uplink card for trunking and CPE access.
Table A-2 PXM Specifications
Category
|
Description
|
Maximum switch fabric throughput
|
2 times OC-12.
|
Control access
(These ports exits on the PXM-UI back card)
|
Control port: RJ-45 connector, EIA/TIA 232, DTE mode, asynchronous interface 19,200 baud, 1 start bit, 1 stop bit, no parity bits.
Maintenance port: RJ-45 connector, EIA/TIA 232, DTE mode, asynchronous interface 9600 baud, 1 start bit, 1 stop bit, no parity bits.
LAN port: RJ-45 connector, 10BASET, 802.3 Ethernet.
|
Uplink ports and connectors
(An uplink card can have one of these number and type of connectors. The wavelength on optical lines is 1310 nm)
|
4 OC-3 multi-mode fiber, SC connectors 4 OC-3 single-mode fiber, intermediate reach, SC connectors 4 OC-3 single-mode fiber, long reach, SC connectors
|
Number of logical ports
|
32 across all physical ports on the uplink card (regardless of line type).
|
LEDs on PXM front card
(LEDs display status, but alarm history is a switch)
|
Status for the card:
• Green means active.
• Red means failed.
• Yellow indicates the standby card.
LAN activity: flashing green indicates activity.
Node alarm:
• Blue indicates critical alarm
• Red indicates major alarm.
• Yellow indicates minor alarm.
Node power (note that each AC power supply also has an LED):
• "DC OK A" is green for okay or red for trouble.
• "DC OK B" is green for okay or red for trouble.
Alarm history: ACO
Port interface (for the uplink port):
• Green means active and okay.
• Red means active and local alarm.
• Yellow means active and remote alarm.
• No light means inactive or not provided.
|
LEDs on back cards
|
Green means active. No light means inactive or not provided.
|
Synchronization
(These clock sources satisfy Stratum 4 requirements)
|
8 kHz clock derived from the following sources:
• Internal 8 kHz clock (10 ppm).
• Service modules or trunk line interfaces.
• External BITS clock port.
• T1 clock rate 1.544 MHz ± 32 ppm.
• E1 clock rate 2.048 MHz ± 50 ppm (can be either sync or data signal).
|
BITS clock interface
|
E1/T1 with an RJ-45 connector.
E1 with an SMB connector.
|
Trunk history counters
|
Ingress, per connection: Number of received cells with CLP = 0. Number of received cells with CLP = 1.
Egress, per connection: Number of received cells. Number of transmitted cells. Number of received cells with EFCI bit set. Number of transmitted cells with EFCI bit set.
|
Connection capacities supported by PXM
|
Maximum number of connections: 16,000 bi-directional channels for local switching. 32,000 bi-directional channels for switching across uplink card.
Maximum aggregate bandwidth: 600 Mbps local switching (service module to service module). 1,200 Mbps switching across uplink.
Cell memory: 256K cells.
|
Processor clock speed and memory specifics
|
Clock speed: 200 MHz internal, 50 MHz external.
Flash memory: 2 Mbytes.
DRAM: 64 Mbytes, upgradeable to 128 Mbytes.
Secondary cache: 512 Kbytes.
BRAM: 128 Kbytes.
Hard disk: 4 Gbytes.
|
Alarm indicators (audible and visual)
|
Central office-compatible alarm indicators and controls through a DB15 connector.
|
Maintenance features
|
Internal isolation loopback. External remote loopback. Hot-pluggable.
|
Card dimensions
|
Front card: 15.65 inches by 16.83 inches (39.75 cm by 42.75 cm) Back cards: 7.25 inches by 4.125 inches (18.42 cm by 10.48 cm)
|
Power
|
Requires -48 VDC, dissipates 150W.
|
AUSM/B-8T1E1 Interface Characteristics
This section contains details for the AUSM/B-8T1E1. For physical characteristics, see Table A-3. For the T1 and E1 characteristics, see Table A-3 and Table A-5, respectively. For ATM interface characteristics, see Table A-6. For statistics and counters, see Table A-7.l
Table A-3 Physical Characteristics of the AUSM/B-8T1E1
Category
|
Description
|
LED Indicators Per Card
|
Active (green), Standby (yellow), Fail (red)
|
LED Indicators Per Line
|
One per line: Active and OK (green) Active and Local Alarm (red) Active and Remote Alarm (yellow)
|
Maintenance/Serviceability
|
Facility loopback via loop up/down per ANSI T1.408 and ATT TR 62411 (T1), CCITT G.7xx (E1) Facility Loopback via Management Console Internal Problem Isolation Loopbacks Hot pluggable
|
Card Size
|
Front card: 7.25" x 16.25" (18.43 cm x 41.28 cm) Back cards: 7" x 4.5" (17.78 cm x 11.43 cm)
|
Power
|
-48 VDC, 30W
|
Safety
|
EN 60950 2nd edition (including EN 41003) UL 1950 2nd edition
|
Compliance
|
T1: G.703, G.824 E1: G.703, G.823
|
ESD
|
IEC 61000-4-2
|
Table A-4 T1 Interface Characteristics
Category
|
Description
|
Line Interface
|
RJ-48 (100 ohms) on the LM-RJ48-8T1 back card
|
Line Rate
|
1.544 Mbps ± 50 bps (T1)
|
Synchronization
|
Transmitter can be loop-timed, receiver, or synchronized to node (normal mode)
|
Line Code
|
Bi-polar 8 Zero Substitution (B8ZS) per ANSI T1.408 (T1)
|
Line Framing
|
Extended Superframe Format (ESF 24 frame multi-frame) per ANSI T1.408
|
ESF Maintenance
|
Bit-oriented alarm and loopback messages of ESF Data Link per ANSI T1.408
|
Input Jitter Tolerance
|
Per ITU-T G.824
|
Output Jitter
|
Per ITU-T G.824 using normal mode synchronization.
|
Physical Layer Alarms
|
LOS, OOF, AIS, RAI
|
Physical Layer Performance Statistics
|
LCV, LES, LSES, CV, ES, MGX 8230, SEFS, AISS, UAS
|
Table A-5 E1 Interface Characteristics
Category
|
Description
|
Line Interface Connector
|
RJ-48 (120 ohms) on LM-RJ48-8E1, or SMB (75 ohms) on LM-SMB-8E1
|
Line Rate
|
2.048 Mbps ± 100 bps
|
Synchronization
|
Transmitter can be: loop timed, receiver, or synchronized to shelf (normal mode)
|
Line Code
|
HDB3 (E1)
|
Line Framing
|
16-frame multi-frame as in G.704
|
Input Jitter Tolerance
|
As specified in ITU G.823 for 2.048 Mbps
|
Output Jitter Generation
|
As specified in ITU G.823 for 2.048 Mbps
|
Physical Layer Alarms
|
LOS, OOF, AIS, RAI
|
Physical Layer Statistics
|
LCV, LES, LSES, CV, ES, MGX 8230, SEFS, AISS, UAS
|
Table A-6 ATM Interface Characteristics
Category
|
Description
|
Standards
|
ATM UNI v3.1, ITU-T G.804, per CCITT I.361.
|
Channel Configuration
|
1000 per card, across any of the T1 or E1 ports.
|
VPI/VCI Ranges
|
VPI: 0-255. VCI: 0-4096.
|
Traffic Classes
|
CBR, VBR, VBR+.
|
UPC Parameters
|
PCR, SCR (VBR), CCDV (CBR).
|
Congestion Control Support
|
ForeSight (toward Network for VBR+).
|
ForeSight Parameters
|
MIR, PIR, Rate Up, Rate Down, QIR, QIR Timeout, IBS.
|
Table A-7 AUSM/B-8T1E1 Statistics and Counters
Counter Type
|
Description
|
Per Port
|
Number of cells received from the interface. Number of cells received with unknown VPI/VCI. Last known VPI/VCI received from the port. Number of cells discarded due to error in Cell Header. Number of cells received with non-zero GRC field. Number of cells transmitted to the interface. Number of cells transmitted for which EFCI was set. Number of egress cells discarded due to service interface physical alarm.
|
Endpoint (channel)
|
|
Ingress
|
Number of cells received from port. Number of cells received from the port with CLP = 1. Number of cells received from the port with EFCI = 1. Number of cells from the port discarded due to queue exceeded QDepth. Number of cells (with CLP) set) discarded due to queue exceeded CLP threshold. Number of cells from the port for which CLP was set due to UPC violations.
|
ATMizer Channel Counters
|
|
Ingress
|
Number of cells transmitted to cell bus. Number of cells to cell bus for which EFCI was set. Number of cells to cell bus discarded due to shelf alarm.
|
Egress
|
Number of cells received from the cell bus. Number of cells discarded due to queue exceeded QDepth (per Egress Q). Number of cells discarded due to queue exceeded CLP threshold (per Egress Q).
Number of cells received with CLP = 1.
|
Other Counters
|
|
Ingress
|
Number of OAM cells discarded. Number of AIS cells received from the port. Number of RDI (FERF) cells received from the port. Number SegmentLpBk cells received from the port. Number of SegmentLpBk cells transmitted to cell bus.
|
Egress
|
Number of OAM cells discarded. Number of AIS cells transmitted to the port. Number of SegmentLpBk cells transmitted to the port. Number of SegmentLpBk cells received from the port.
|
Diagnostic Statistics
|
Peak Queue Depth (Ingress: per channel).
|
FRSM-2CT3 Specifications
This section provides details for the FRSM-2CT3. Topics consist of the following:
•
Transport technology standards with which the card complies (Table A-8)
•
General physical attributes of the card, such as LEDs on the faceplate (Table A-9)
•
Line and framer characteristics (Table A-10 and "FRSM-2CT3 Framer" section)
•
Line alarms ("FRSM-2CT3 Line Alarms")
Table A-8 Frame Relay Interface Standards
Interface
|
Standard
|
Frame Relay Interface
|
ANSI T1.618, 2-octet header
|
ATM Layer
|
CCITT I.361 and ATM UNI v3.1
|
AAL Layer
|
AAL5 per ITU-T I.363
|
FR-Cell Interworking
|
Per ITU-T I.555 and I.36x.1, as summarized in "ATM-to-Frame Relay Interoperability Implementation Agreement" v 1.0
|
Table A-9 FRSM-2CT3 Front Card Physical Characteristics
Feature
|
Significance or Value
|
Power
|
-48 VDC, 60W (estimated)
|
Card Status Indicator LEDs
|
Active (Green), Failed (Red), Standby (Yellow)
|
Line Status Indicator LEDs
|
Active & Okay (Green), Active & Local Alarm (Red), Active & Remote Alarm (Yellow)
|
Reliability
|
> 85000 hours MTBF (target)
|
Card Size
|
7.25 inches by 16.5 inches
|
Table A-10 FRSM-2CT3 Line Level
Feature
|
Significance or Value
|
Number of T3 Lines
|
Two
|
Line Interface Connector
|
75 ohm BNC
|
Line Rate
|
44.736 Mbps +/- 20 ppm
|
Line Coding
|
B3ZS
|
Transmit Timing
|
Normal or Loop timed
|
Input Jitter Tolerance
|
Per GR-449-CORE, ITU-T G.824
|
Output Jitter
|
0.05 UI maximum with jitter-free input clock
|
Output Pulse
|
Per T1.102.1993
|
FRSM-2CT3 Framer
The FRSM-2CT3 line framer:
•
Supports M13 or C-bit parity format.
•
Performs required inversion of second and fourth multiplexed DS1 streams per ANSI T1.107.
•
Generates loop-up code to the far-end device to loop back any of the DS1s or entire DS3 signal stream by way of the FEAC channel.
•
Automatically detects the incoming loop-up codes from the far-end device as well as loop back any of the DS1s or entire DS3 signal stream back to the far-end device. The loopback occurs at the M13 framer chip.
FRSM-2CT3 Line Alarms
For line alarms, the FRSM-2CT3 supports:
•
Detection and generation of Remote Alarm Indicator (RAI) signal (also known as FERF and Yellow signal)
•
Detection and generation of Alarm Indication Signal (AIS)
•
Detection of Out of Frame (OOF) condition
•
Detection of Loss of Frame (LOS) condition
•
Automatic generation of Far End Block Error (FEBE)
FRSM-2T3E3 Specifications
This section provides details for the FRSM-2T3E3. Where appropriate, it has separate sections for T3 and E3 technologies. Topics consist of the following:
•
Transport technology standards with which the card complies (Table A-11)
•
General physical attributes of the card, such as LEDs on the faceplate (Table A-12)
•
Line and framer characteristics for T3 operation (Table A-13 and "T3 Framer Level")
•
Line and framer characteristics for E3 operation (Table A-14 and "E3 Framer Level")
•
Line alarms ("FRSM-2T3E3 Line Alarms")
Table A-11 Frame Relay Interface Standards
Interface
|
Standard
|
Frame Relay Interface
|
ANSI T1.618, 2-octet header
|
ATM Layer
|
CCITT I.361 and ATM UNI v3.1
|
AAL Layer
|
AAL5 ITU-T I.363
|
FR-Cell Interworking
|
Per ITU-T I.555 and I.36x.1, as summarized in ATM-to-Frame Relay Interoperability Implementation Agreement v 1.0
|
Table A-12 FRSM-2T3E3 Front Card Physical Characteristics
Feature
|
Significance or Value
|
Power
|
-48 VDC, 60W (estimated)
|
Card Status Indicator LEDs
|
Active (Green), Failed (Red), Standby (Yellow)
|
Line Status Indicator LEDs
|
Active & Okay (Green), Active & Local Alarm (Red), Active & Remote Alarm (Yellow)
|
Reliability
|
> 85000 hours MTBF (target)
|
Card Size
|
7.25 inches by 16.5 inches
|
FRSM-2T3E3 T3 Line
The T3 line characteristics appear in Table A-13.
Table A-13 T3 Line Level
Feature
|
Significance or Value
|
Number of T3 Lines
|
Two
|
Line Interface Connector
|
75 ohm BNC
|
Line Rate
|
44.736 Mbps +/- 20 ppm
|
Line Coding
|
B3ZS
|
Transmit Timing
|
Normal or Loop timed
|
Input Jitter Tolerance
|
Per GR-499-CORE, ITU-T G.824
|
Output Jitter
|
0.05 UI maximum with jitter-free input clock
|
Output Pulse
|
Per ANSI T1.102
|
T3 Framer Level
For the framing characteristics of T3 operation, the FRSM-2T3E3:
•
Supports C-bit parity and M13 DS3 format.
•
Frames to a DS3 signal with a maximum average reframe time that meets the requirements set by TR-TSY-000009 and GR-499-CORE.
•
Detects the alarm indication signal (AIS) in milliseconds in the presence of a 10-3 bit error rate.
•
When in-frame, indicates M-bit or F-bit framing errors as well as P-bit errors. In C-bit parity mode, it also indicates both C-bit parity errors and far end block errors.
FRSM-2T3E3 E3 Line
For characteristics of the line on an FRSM-2T3E3 with an E3 back card see figure A14:
Table A-14 E3 Line Level
Feature
|
Significance or Value
|
Number of E3 Lines
|
Two
|
Line Interface Connector
|
75 ohm BNC
|
Line Rate
|
34.368 Mbps +/- 20 ppm
|
Line Coding
|
HDB3
|
Transmit Timing
|
Normal or Loop timed
|
Input Jitter Tolerance
|
Per ITU-T G.823
|
Output Jitter
|
0.05 UI maximum with jitter-free input clock per AT&T TR54014
|
Output Pulse
|
Per ITU-T G.703
|
E3 Framer Level
For line framing, the E3 operation of the FRSM-2T3E3 complies with ITU-T G.751.
FRSM-2T3E3 Line Alarms
For line alarms, the FRSM-2T3E3 supports:
•
Detection and generation of Remote Alarm Indicator (RAI) signal (also known as FERF and Yellow signal)
•
Detection and generation of Alarm Indication Signal (AIS)
•
Detection of Out of Frame (OOF) condition
•
Detection of Loss of Frame (LOS) condition
•
Automatic generation of Far End Block Error (FEBE)
Statistics and Counter Specifications
See the section titled "Counters and Statistics for FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2" for lists of applicable statistics and counters.
FRSM-HS2 Specifications
The FRSM-HS2 is the Frame Relay module with two HSSI ports. The topics in this section are:
•
Transport technology standards with which the card complies (Table A-15)
•
General physical attributes of the card, such as LEDs on the faceplate (Table A-16)
•
Line and framer characteristics (Table A-17)
For lists of the counters and statistics that are available on the FRSM-VHS series of cards, see the section titled "Counters and Statistics for FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2."
Table A-15 Frame Relay Interface Standards
Interface
|
Standard
|
Frame Relay Interface
|
ANSI T1.618, 2-octet header
|
ATM Layer
|
CCITT I.361 and ATM UNI v3.1
|
AAL Layer
|
AAL5 per ITU-T I.363
|
FR-Cell Interworking
|
Per ITU-T I.555 and I.36x.1, as summarized in ATM-to-Frame Relay Interoperability Implementation Agreement v 1.0
|
Table A-16 FRSM-HS2 Physical Characteristics
Feature
|
Significance or Value
|
Power
|
-48V, 75W (estimated) The SCSI2-2HSSI back card consumes 5 watts at 5 VDC and 6 watts at -5 VDC.
|
Card Status Indicator LEDs
|
Active (Green), Failed (Red), Standby (Yellow)
|
Line Status Indicator LEDs
|
Active & Okay (Green), Active & Local Alarm (Red), Active & Remote Alarm (Yellow)
|
Reliability
|
> 85000 hours MTBF (target)
|
Card Size
|
Front card: 7.25" x 16.25" (18.43 cm x 41.28 cm) Back card: 7" x 4.5" (17.78 cm x 11.43 cm)
|
Table A-17 FRSM-HS2 Line Characteristics
Feature
|
Significance or Value
|
Number of HSSI Lines
|
Two
|
Connector Type
|
SCSI-2
|
Signaling Rate
|
52 Mbps max
|
Line Alarms
|
• Control lead is inactive
• Recovered clock does not match configured line rate
|
Synchronization
|
Transmitter may be either loop-timed to Receiver (DTE mode) or synchronized to shelf (DCE mode)
|
Electrical Interchange Characteristics
|
ITU-T V.12
|
Counters and Statistics for FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2
This section lists counters and statistics that apply to most types of cards in the FRSM-VHS group.
Table A-18 Counters per Line
Counter
|
Received frames lost due to aborts
|
Received frames lost due to illegal header (EA bit)
|
Received frames lost due to CRC errors
|
Received frames with bit alignment errors
|
Received frames with unknown DLCI
|
Received frames with illegal frame length
|
Received good frame
|
| |
Transmit frames lost due to under-run/Abort count
|
Transmit good frame
|
LMI status inquiry request count
|
LMI signaling protocol (keep-alive time-out count)
|
LMI sequence number error count
|
LMI status transmit count (in response to request)
|
LMI update status transmit count (in response to configuration changes
|
Frames with FECN set count
|
Frames with BECN set count
|
DE frames discarded count
|
Number of frames reassembled but discarded due to service interface physical layer alarm
|
Table A-19 Service-Related Statistics
Service Statistic
|
Number of received frames
|
Number of bytes received
|
Number of frames received with DE=1
|
Number of frames received but discarded
|
Number of received bytes discarded
|
Number of frames received but discarded due to
• CRC error
• Illegal frame length
• Alignment error
• Abort
|
Number of frames reassembled and transmitted
|
Number of frames reassembled and transmitted with DE=1
|
Number of frames discarded due to reassembly errors
|
Number of frames transmitted
|
Number of bytes transmitted
|
Number of frames transmitted with DE set
|
Number of frames transmitted during LMI logical port alarm
|
Frames FECN set count
|
Frames BECN set count
|
Number of transmit frames discarded
|
Number of transmit bytes discarded
|
Number of transmit frames discarded due to:
• CRC error
• Illegal frame length
• Alignment error
• Abort
• DE egress queue threshold exceeded
• Physical link failure
|
Table A-20 ATM Cell-Related Statistics
ATM Cell Statistic
|
Number of cells transmitted to PXM
|
Number of cells discarded due to intershelf link alarm
|
Number of cells transmitted with CLP bit set
|
Number of AIS cells transmitted
|
Number of FERF cells transmitted
|
Number of BCM cells transmitted
|
Number of end-to-end loop back cells transmitted
|
Number of segment loop back cells transmitted
|
Number of cells received from PXM
|
Number of cells received with CLP bit set
|
Number of AIS cells received
|
Number of FERF cells received
|
Number of BCM cells received
|
Number of end-to-end loopback cells received
|
Number of segment loopback cells received
|
Number of OAM cells discarded due to CRC-10 error
|
Table A-21 Diagnostic-Related Statistics
Diagnostic Statistic
|
Header of last cell with unknown LCN
|
Header of last received frame with unknown DLCI
|
ECN current queue depth
|
Table A-22 Troubleshooting Statistics
Troubleshooting Statistic
|
ECN current queue depth, per channel
|
FRSM-8T1 Specification
This section provides information on the T1 operation of the FRSM-8T1E1 card set. Topics are
•
General physical information about the card set (Table A-23)
•
Information about the Frame Relay service (Table A-24)
•
System-level interface (Table A-25)
•
Statistics and counters (Table A-26)
Table A-23 General Card Specifications
Category
|
Description
|
Indicators per card
|
Active (Green), Standby (Yellow), Fail (Red)
|
Indicators per line
|
Active & Okay (Green) Active & Local Alarm (Red) Active & Remote Alarm (Yellow)
|
Line Interface connector
|
RJ-48 when used with RJ48-8T1 back card
|
Line Rate
|
1.544 Mbps ± 50 bps
|
Line Framing
|
ESF per ATT TR 54016
|
Maintenance/Serviceability Features
|
Internal Problem Isolation Loopbacks Hot-pluggable cards
|
Reliability, MTBF
|
> 65000 hours
|
Card Size
|
FRSM-8T1: 7.25" x 16.25" LM-DB15-8T1: 7.0" x 4.5" Power: -48 VDC, 30W with 8 active T1 lines
|
Table A-24 Frame Relay Service With T1 Lines
Category
|
Description
|
Synchronization
|
Transmitter may be either loop-timed to receiver or synchronized to shelf (called normal mode)
|
Input Jitter Tolerance
|
Per ITU-T G.824
|
Output Jitter Generation
|
Per ITU-T G.824 using normal mode synchronization
|
Physical Layer Alarms
|
LOS, OOF, AIS, RAI
|
Number of Frame Relay Ports
|
One-a single Frame Relay stream occupying N consecutive time slots
|
Frame Relay Interface Rates
|
Either of the following:
• 56 Kbps
• N x 64 Kbps (where N is the number of consecutive time slots)
|
Frame Relay Interface
|
Per ANSI T1.618, 2-octet header
|
Frame Relay Performance Counters (per Port; N x DS0)
|
Received frames discarded due to Aborts Received frames discarded due to illegal header (EA bit)(s) Received frames discarded due to CRC errors (s) Received frames discarded due to alignment errors (s) Received frames discarded due to unknown DLCI (s) Received frames discarded due to illegal frame length (s) Received frames discarded due to DE threshold exceeded Received frames with DE already set Received frames with FECN already set Received frames with BECN already set Received frames tagged FECN Received frames (s) Received bytes (s) Transmit frames discarded due to underrun Transmit frames discarded due to Abort Transmit frames discarded due to egress Q-depth exceeded (s) Transmit bytes discarded due to egress Q-depth exceeded (s) Transmit frames discarded due to egress DE threshold exceeded Transmit frames (s)
|
| |
Transmit bytes(s) Transmit Frames with FECN set (s) Transmit Frames with BECN set (s)
|
| |
LMI receive status inquiry request count (s) LMI transmit status inquiry request count LMI invalid receive status count (s) LMI signaling protocol (keep alive time-out count) (s) LMI sequence number error count (s) LMI receive status transmit count (in response to request) LMI transmit status transmit count (in response to request) Transmit frames during LMI alarm (s) Transmit bytes during LMI alarm (s) LMI update status transmit count (in response to configuration changes)
|
Diagnostics (per port)
|
Last unknown DLCI received
|
Table A-25 System Interface
Category
|
Description
|
ATM Layer
|
Per ITU-T I.361 and ATM UNI v3.1
|
AAL Layer
|
AAL5 per ITU-T I.363
|
FR-Cell Interworking
|
Per ITU-T I.555 and I.36x.1, as summarized in Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FRF.5
|
Table A-26 List of Counters
Category
|
Description
|
Channels (endpoints) per card
|
256, which you can allocate across any of the interfaces
|
Service Counters
Note that an (s) at the end of the description means the data in the counter is usable as a statistic.
|
Number of frames received (s) Number of bytes received (s) Number of frames received with DE already set (s) Number of bytes received with DE already set (s) Number of frames received with unknown DLCI Number of frames received but discarded (s) Number of received bytes discarded (s) Number of received bytes discarded due to exceeded Q-depth (s) Number of frames received and discarded due to: intershelf alarm exceeded DE threshold (s) exceeded Q depth (s) Number of frames received with FECN set Number of frames received with BECN set Number of frames received tagged FECN Number of frames received tagged BECN
|
| |
Number of frames transmitted (s) Number of bytes transmitted (s)
|
| |
Number of frames transmitted with DE set (s) Number of frames discarded due to reassembly errors (s) Number of frames transmitted during LMI logical port alarm(s) Number of frames transmitted with FECN set (s) Number of frames transmitted with BECN set (s) Number of transmit frames discarded (s) Number of transmit bytes discarded Number of transmit frames discarded due to: CRC error (s) egress Q depth exceeded (s) egress DE threshold exceeded source abort physical link failure (T1) ATM cells: Number of cells transmitted to PXM Number of cells transmitted with CLP bit set Number of OAM AIS cells transmitted (s) Number of OAM FERF cells transmitted (s) Number of BCM cells transmitted Number of OAM end-to-end loopback cells transmitted (s) Number of OAM segment loopback cells transmitted Number of cells received from PXM Number of cells received with CLP bit set Number of OAM AIS cells received (s) Number of OAM FERF cells received (s) Number of BCM cells received Number of OAM end-to-end loopback cells received (s) Number of OAM segment loopback cells received Number of OAM cells discarded due to CRC-10 error (s)
|
Statistics
|
If any of the counters in the preceding category of Service Counters includes an "(s)," you can configure it for statistics usage
|
Diagnostics
|
Last unknown LCN received Number of cells with unknown LCN
|
FRSM-8E1 Specification
This section provides information on the E1 operation of the FRSM-8T1E1 card set. Topics are:
•
General physical information about the card set (Table A-27)
•
Information about the Frame Relay service (Table A-28)
•
System-level interface (Table A-29)
•
Statistics and counters (Table A-30)
Table A-27 General Card Specifications
Category
|
Description
|
Line Interface connector
|
RJ-48 when used with RJ-48-8E1 line module. SMB when used with SMB-8E1 line module
|
Line Rate
|
2.048 Mbps ± 100 bps
|
Synchronization
|
Transmitter may be either loop-timed to receiver or synchronized to shelf (normal mode)
|
Input Jitter Tolerance
|
Per ITU-T G.823
|
Output Jitter Generation
|
Per ITU-T G.823
|
Physical Layer Alarms
|
LOS, OOF, AIS, RAI
|
Indicators per card
|
Active (Green), Standby (Yellow), Fail (Red)
|
Indicators per line
|
Active & Okay (Green) Active & Local Alarm (Red) Active & Remote Alarm (Yellow)
|
Maintenance/Serviceability Features
|
Internal Problem Isolation Loopbacks Hot-pluggable cards
|
Reliability, MTBF
|
> 65000 hours
|
Card Size
|
FRSM-8E1: 7.25" x 16.25" (18.43 cm x 41.28 cm) RJ48-8E1: 7.0" x 4.5" (17.78 cm x 11.43 cm) SMB-8E1: 7.0" x 4.5" (17.78 cm x 11.43 cm)
|
Power
|
-48 VDC, 30W with 8 active E1 lines
|
Table A-28 Frame Relay Service With E1 Lines
Category
|
Description
|
Number of Frame Interfaces
|
1-31 occupying N, where 1 < N < 31. Sum of all < 31 for CCS or 1-30 for CAS.
|
Frame Relay Interface Rates
|
Either 56 Kbps orN x 64 Kbps, where N is the same as defined in the preceding item the preceding item "Number of Frame Interfaces."
|
Ingress
|
8000-cell buffer shared between virtual channels/paths standard usage parameter control (UPC) Selective Cell Discard Virtual Circuit Queuing EFCI setting per VC
|
Egress
|
8000-cell storage capacity shared between four ports Up to 12 user-selectable egress queues per port Selective Cell Discard EFCI setting per Queue
|
Frame Relay Interface
|
Per ANSI T1.618, 2-octet header
|
Frame Relay Performance Counters (per Port; N x DS0):
|
Received frames discarded due to Aborts Received frames discarded due to illegal header (EA bit)(s) Received frames discarded due to CRC errors (s) Received frames discarded due to alignment errors (s) Received frames discarded due to unknown DLCI (s) Received frames discarded due to illegal frame length (s) Received frames discarded due to DE threshold exceeded Received frames with DE already set Received frames with FECN already set Received frames with BECN already set Received frames tagged FECN Received frames (s) Received bytes (s)
|
| |
Transmit frames discarded due to underrun Transmit frames discarded due to Abort Transmit frames discarded due to egress Q-depth exceeded (s) Transmit bytes discarded due to egress Q-depth exceeded (s) Transmit frames discarded due to egress DE threshold exceeded Transmit frames (s) Transmit bytes(s) Transmit Frames with FECN set (s) Transmit Frames with BECN set (s) LMI receive status inquiry request count (s) LMI transmit status inquiry request count LMI invalid receive status count (s) LMI signaling protocol (keep alive time-out count) (s) LMI sequence number error count (s) LMI receive status transmit count (in response to request) LMI transmit status transmit count (in response to request) Transmit frames during LMI alarm (s) Transmit bytes during LMI alarm (s) LMI update status transmit count (in response to configuration changes)
|
Diagnostics (per port):
|
Last unknown DLCI that arrived
|
Table A-29 System Interface
Category
|
Description
|
ATM Layer
|
Per ITU-T I.361 and ATM UNI v3.1
|
AAL Layer
|
AAL5 per ITU-T I.363
|
FR-Cell Interworking
|
Per ITU-T I.555 and I.36x.1, as summarized in Frame Relay Forum, FR/ATM PVC Interworking Implementation Agreement FERF.5
|
Table A-30 List of Counters
Category
|
Description
|
Channels (Endpoints)
|
256 per card—can be allocated across any of the Frame Relay interfaces
|
Counters
|
Service Counters: Number of frames received (s) Number of bytes received (s) Number of frames received with DE already set (s) Number of bytes received with DE already set (s) Number of frames received with unknown DLCI Number of frames received but discarded (s) Number of received bytes discarded (s) Number of received bytes discarded due to exceeded Q-Depth (s) Number of frames received and discarded due to
• intershelf alarm
• exceeded DE threshold (s)
• exceeded Q depth (s)
Number of frames received with FECN set Number of frames received with BECN set
|
| |
Number of frames received tagged FECN Number of frames received tagged BECN Number of frames transmitted (s) Number of bytes transmitted (s) Number of frames transmitted with DE set (s) Number of frames discarded due to reassembly errors (s) Number of frames transmitted during LMI logical port alarm(s) Number of frames transmitted with FECN set (s) Number of frames transmitted with BECN set (s) Number of transmit frames discarded (s) Number of transmit bytes discarded Number of transmit frames discarded due to: CRC error (s) egress Q depth exceeded (s) egress DE threshold exceeded source abort physical link failure (T1)
|
| |
ATM cells: Number of cells transmitted to PXM Number of cells transmitted with CLP bit set Number of OAM AIS cells transmitted (s) Number of OAM FERF cells transmitted (s) Number of BCM cells transmitted Number of OAM end-to-end loopback cells transmitted (s) Number of OAM segment loopback cells transmitted Number of cells received from PXM Number of cells received with CLP bit set Number of OAM AIS cells received (s) Number of OAM FERF cells received (s) Number of BCM cells received Number of OAM end-to-end loopback cells received (s) Number of OAM segment loopback cells received Number of OAM cells discarded due to CRC-10 error (s) Statistics: All of the above counters followed by an (s) can be configured as statistics. Diagnostics: Last unknown LCN received Cells with unknown LCN count Card General
|
Circuit Emulation Service Module for T1 Operation
This section contains operational details for the CESM 8T1E1 with the RJ48-8T1 back card.
Table A-31 CESM 8T1 Card Information
Category
|
Description
|
Back Card
|
RJ48-8T1
|
Line Rate
|
T1: 1.544 Mbps ±50 bps
|
Transmit Clocking
|
Normal clock or SRTS generated
|
Line Coding
|
B8ZS
|
Frame mode
|
ESF
|
Line alarms
|
Loss or Signal (LOS) Loss of Frame (LOF) Loss of multiframe (LOMF) Remote loss of signal or frame (RAI) All ones received (AIS) Bi-polar violation
|
Alarm indication times
|
Near end alarm up-count Near end alarm down-count Near end alarm maximum count Far end alarm up-count Far end alarm down-count Far end alarm maximum count
|
Supported OAM cells
|
AIS FERF End-to-end loopback Segment loopback RTD loopback BCM
|
Physical Layer Performance Statistics
|
N/A
|
LED Indicators Per Card
|
Active (green), Failed (red), Standby (yellow)
|
BERT
|
Active (green), Errors (yellow)
|
1:N Redundancy
|
Active (green)
|
Indicator for each T1
|
Active (green)
|
Reliability, MTBF
|
|
Card Size
|
Front card: 7.25" x 16.25" (18.43 cm x 41.28 cm) Back card: 7" x 4.5" (17.78 cm x 11.43 cm)
|
Power
|
48 VDC, 30W
|
Loopbacks
|
On or Off
|
Circuit Emulation Service Module for E1 Operation
This section contains operational details for the CESM-8T1E1 with an E1 back card.
Table A-32 CESM 8E1 Card Set Details
Category
|
Description
|
Back Card
|
RJ48-8E or SMB-8E1
|
Line Rate
|
E1: 2.048 Mbps ± 100 bps (50 ppm)
|
Transmit Clocking
|
Normal clock or SRTS generated
|
Line Coding
|
HDB3
|
Frame mode
|
single-frame multi-frame
|
Line alarms
|
Loss or Signal (LOS) Loss of Frame (LOF) Loss of multi-frame (LOMF) Remote loss of signal or frame (RAI) All ones received (AIS) Bi-polar violation
|
Alarm indication times
|
Near end alarm up-count Near end alarm down-count Near end alarm maximum count Far end alarm up-count Far end alarm down-count Far end alarm maximum count
|
Supported OAM cells
|
AIS FERF End-to-end loopback Segment loopback RTD loopback BCM
|
Physical Layer Performance Statistics
|
N/A
|
Indicators
|
|
Card-level
|
Active (green), Failed (red), Standby (yellow)
|
BERT
|
Active (green), Errors (yellow)
|
1:N Redundancy
|
Active (green)
|
Indicator for each T1
|
Active (green)
|
Reliability, MTBF
|
|
Card Size
|
< |