Reliability, Availability, and Serviceability

Diagnostics

Diagnostics Examples

Diagnostics Tests

PXM1E Diagnostics Tests

PXM45 Diagnostics Tests


Reliability, Availability, and Serviceability


Both the PXM45 and the PXM1E support the following reliability, availability, and serviceability (RAS) features:

Power On Self Test (POST)

Hardware Monitoring Module (HMM)

Online diagnostics

Offline diagnostics

Enhanced alarm reporting

The POST and HMM features are transparent to the user. However, the dsppostresults command can be used to display the POST results. POSTs are a set of tests that run at boot-up time. POSTS cannot be disabled.

Diagnostics

Diagnostics commands can be used to isolate or troubleshoot problems. The following procedure shows the steps for identifying problems or failures:


Step 1 Observe card alarms.

MGX8850.7.PXM.a>dspndalms

Step 2 Observe hardware or diagnostic alarms and slot numbers

MGX8850.7.PXM.a>dspcdalms

Step 3 If there are hardware alarms, change card to appropriate slot .

MGX8850.7.PXM.a>cc slot

Step 4 Display alarms to identify the device.

MGX8850.7.PXM.a>dsphwalms

Step 5 Display errors on device.

MGX8850.7.PXM.a>dspdeverr device

Step 6 If there are diagnostic alarms, change card to appropriate slot

MGX8850.7.PXM.a>cc slot

Step 7 Display diagnostics results.

MGX8850.7.PXM.a>dspdiagresults

Table G-1 shows some of the other commands that can be used to isolate and troubleshoot problems. For details about these commands refer to the Cisco MGX 8850 (PXM45/PXM1E), Cisco MGX 8950, Cisco MGX 8830, and Cisco MGX 8880 Command Reference, Release 5.

Table G-1 RAS-Related Diagnostics, Alarm, and POST Commands

Command
Description

cnfdiag

Configures (enables/disables) online diagnostics and schedules offline diagnostics for a specific slot.

cnfdiagall

Configures (enables/disables) online diagnostics and schedules offline diagnostics for all slots.

dspdiagcnf

Displays the configuration of online and offline diagnostics

dspdiagstatus

Displays the status of online and offline diagnostics on all slots and indicates whether diagnostics is ready to be enabled or not.

dspdiagstat

Displays the statistics of online and offline diagnostics execution for a specific slot.

dspdiagerr

Displays errors of online and offline diagnostics execution on all slots.

dspdiagtests

Displays a list of all diagnostics tests.

clrdiagstat

Clears the statistics of executed online and offline diagnostics for a specific slot.

clrdiagerr

Clears the errors reported by online and offline diagnostics for a specific slot.

dspdeverr

Displays the error types and error counts for a specific device in a slot.

abortofflinediag

Stops the currently running offline diagnostics test.

dspdeverrhist

Displays the history of error types and error counts for a specific device in a slot.

dspdiagresults

Displays the diagnostics test results and alarm conditions for a specific slot.

dsphwalms

Displays a summary of errors and alarms for all devices in a slot.

dsppostresults

Displays the Power on Self Test (POST) results.


Diagnostics Examples

The following example shows the display output for the dspdiagresults command:

MGX8850.7.PXM.a>  dspdiagresults
       --------------------------------------------------------
                Online Diagnostics Test Summary
       --------------------------------------------------------
 Id    Name                 En     #Att  #Fail  #Pass  Alarm  Result 
 --    ----                 --     ----  -----  -----  -----  -----
  1    Data Path            Y      2868     0    2868   None  Pass  
  2    Trap Freq Monitor    Y      1434     0    1434   None  Pass  
  3    Memory Access        Y      2868     0    2868   None  Pass  
  4    Atlas Reg Access     Y      2868     0    2868   None  Pass  
  5    Atlas Sram Access    Y      2868     0    2868   None  Pass  
  6    Framer/LIU Access    Y      2868     0    2868   None  Pass  
  7    Elmer Access         Y      2868     0    2868   None  Pass  
  8    Flash CheckSum       Y      2868     0    2868   None  Pass  
  9    Ethernet Ping        Y      2868     0    2868   None  Pass  
 10    QE RAM Access        Y      2868     0    2868   None  Pass  
 11    HDsk PCI Access      Y      2868     0    2868   None  Pass  
 12    HDsk Rd/Wr           Y        95     0      95   None  Pass  
 13    CBC RAM Access       Y      2868     0    2868   None  Pass  
 14    BRAM checksum        Y      2868     0    2868   None  Pass  
 15    Control Path         Y      28680    0   28680   None  Pass  

The following example shows the display output for the dsppostresults command:

MGX8850.7.PXM.a> dsppostresults

--------------------------------------------------------
          Power On Self Test Results
--------------------------------------------------------
Test Name            Result      Description          
---------------      ---------   ---------------
BRAM Checksum        PASS        
QE RAM               PASS        
CBC RAM              PASS        
Ethernet Reg         NOT DONE    Test Not Required    
PCI-IDE Reg          PASS        
Clock Mux            PASS        
Framer 1 Access      PASS        
Framer 2 Access      PASS        
Framer 3 Access      PASS        
Framer 4 Access      PASS        
ATLAS 1 RAM          PASS        
Hard Disk Access     PASS        

The following example shows the display output for the dsphwalms command:

MGX8850.7.PXM.a>dsphwalms

   Device       Alarms 
   -------      ------ 
   DISK None    
   ATLAS (1)    None
   ATLAS (0)    None  
   NILE4        None
   CBC (0)      None   
   CBC (1)      None   
   QE1210 (1)   None   
   QE1210 (0)   None   

 Use dspdeverr <device> to see more detail.

The following example shows the display output for the dspdeverr command:

MGX8850.7.PXM.a>dspdeverr QE1210

PXM               System Rev: 04.00   Dec. 19, 1999 07:32:33 GMT
MGX8850            Node Alarm: CRITICAL
 CURRENT ERROR COUNT FOR DEVICE QE1210 (1)  (Alarm :  None) 
 --------------- ---------  ---------- ------ ----------- --------------

   Error Type        Total Errors            
   --------------    -----   ------            
   Rx HW Err         0
   DTE ProcErr       0
   RAM ERR           0


 CURRENT ERROR COUNT FOR DEVICE QE1210  (0)   (Alarm :  None) 
 -------------- ----------- ---------- -----  ------------ -------------

   Error Type      Total Errors            
   -------------   -------- -------            
   Rx HW Err       0
   DTE ProcErr     0
   RAM ERR         0

The following example shows the display output for the dspdeverrhist command:

MGX8850.7.PXM.a>dspdeverrhist QE1210
PXM               System Rev: 04.00   Dec. 19, 1999 07:32:33 GMT
MGX8850            Node Alarm: CRITICAL

 HISTORY ERROR COUNT FOR DEVICE QE1210  (1)
 ------------   ----- ----- --- ------ --------------

   Error Type      Total Errors            
   -------------   ------- ------            
   Rx HW Err       0
   DTE ProcErr     0
   RAM ERR         0


 HISTORY ERROR COUNT FOR DEVICE QE1210  (0)
 ------- ----- ----- --- ------ ------------------------------------------

   Error Type       Total Errors            
   ---------------  ------- ------            
   Rx HW Err        0
   DTE ProcErr      0
   RAM ERR          0

MGX8850.8.PXM.a > dspdiagtests
-------------------------------------------
        Online Diagnostic Tests
 Id TestName
 -- --------
 1 Utopia Test          
 2 Path Test            
 3 Xbar Test            
 4 Trap Freq Monitor    
 5 Memory Access        
 6 Elmer Access         
 7 Flash Checksum       
 8 Ethernet Ping        
 9 QE RAM Access        
10 HDD PCI Access       
11 HDD R/W              
12 CBC RAM Access       
13 BRAM Checksum        

MGX8850.8.PXM.a >

Diagnostics Tests

This section lists the diagnostics tests for the PXM1E and PXM45.

PXM1E Diagnostics Tests

The following tests are valid on the PXM1E.

PXM1E Power On Self-Tests (POST)

BRAM checksum

QE RAM

CBC RAM

Ethernet Register Access

PCI/IDE Register Access

Clock Mux Validation

Framer Access

Atlas1 RAM Access

Atlas2 RAM Access

Hard Disk Access

PXM1E Path tests

Data Path

Control Path

PXM1E Device Tests

Atlas Register Access

Atlas SRAM Access

Framer/LIU Access

Trap Frequency Monitor

Elmer Access

Flash Checksum

Ethernet Ping

QE RAM Access

HDD PCI Access

HDD R/W

CBC RAM Access

BRAM checksum

Memory Access

PXM45 Diagnostics Tests

The following tests are valid on the PXM45.

PXM45 Power On Self-Tests (POST)

BRAM Checksum

QE RAM

CBC RAM

Ethernet Register

PCI/IDE Register Access

Clock Mux Validation

Hard Disk Access

PXM45 Path Tests

Utopia Loopback

Path Test

Crossbar test

Device Tests

QE RAM Access

CBC RAM Access

Flash Checksum

HDD R/W

HDD PCI Access

Trap Frequency Monitor

Ethernet Ping

BRAM checksum

Memory Access