Document ID: 45922
Contents
Introduction
Prerequisites
Requirements
Components Used
Conventions
Problem
Solution
Related Information
Introduction
This document describes how to recover the PXM1E module from the Failed state that is caused by moving the PXM1E from an MGX 8830 chassis to an MGX 8850 chassis.
Prerequisites
Requirements
Readers of this document should be knowledgeable of the following:
-
Cisco PXM1E module
-
Cisco MGX 8800 series switches
Components Used
This document is not restricted to specific software and hardware versions.
Conventions
For more information on document conventions, see the Cisco Technical Tips Conventions.
Problem
The following dspcd command output example from a PXM1E shows the card in the Failed state:
|
dspcd |
|---|
HJO System Rev: 03.00 Oct. 13, 2003 15:12:53 CDT
MGX8850 Node Alarm: UNKNOWN
Slot Number 7 Redundant Slot: 8
Front Card Upper Card Lower Card
---------- ---------- ----------
Inserted Card: PXM1E-T3E3-155 UI Stratum3 ---
Reserved Card: PXM1E-T3E3-155 UI Stratum3 FRU-8T3E3-4OC3
State: Failed Active Empty Resvd
Serial Number: SAG06290ERX SAG06320BJC ---
Prim SW Rev: 3.0(23.202) --- ---
Sec SW Rev: 3.0(23.202) --- ---
Cur SW Rev: 3.0(23.202) --- ---
Boot FW Rev: 3.0(23.202) --- ---
800-level Rev: A0 C0 ---
800-level Part#: 800-18604-04 800-08932-02 ---
CLEI Code: BA4AY80BAB BA7IBCLAAA ---
Reset Reason: On Reset From Shell
Card Alarm: UNKNOWN
Failed Reason: SHM_CDF_BKPL_NVID_MISMATCH
Miscellaneous Information:
Type <CR> to continue, Q<CR> to stop:
HJO System Rev: 03.00 Oct. 13, 2003 15:12:53 CDT
MGX8850 Node Alarm: UNKNOWN
Crossbar Slot Status: EMPTY
Alarm Causes
------------
_UNKNOWN_.7.PXM.if > dspcd 7
|
When the PXM1E is moved from an MGX 8830 chassis to an MGX 8850 chassis, the Failed Reason indicates a mismatch on the backplane—SHM_CDF_BKPL_NVID_MISMATCH. The node is in the UNKNOWN state.
Solution
You must use the shellConn prompt shmFailRecoveryHelp command, followed by option 3 (shmRecoverIgRbldDisk), to recover the PXM1E to the ACTIVE state. The following example shows the shellConn command and option:
|
shmFailRecoveryHelp |
|---|
_UNKNOWN_.7.PXM.if > sh pxm1e> shmFailRecoveryHelp * Shell commands to recover from SHM failures: * Recovery Method Recovery Function * =============== ================= * 1. Clear all configurations shmRecoverClrallcnf * 2. Rebuild from Disk shmRecoverRbldDisk * 3. Ignore Nativity * and Rebuild from Disk shmRecoverIgRbldDisk * 4. Program NVRAM shmRecoveryNvramHelp value = 1 = 0x1 pxm1e> shmRecoverIgRbldDisk |
Related Information
- Cisco WAN Switching Solutions - Cisco Documentation
- Guide to New Names and Colors for WAN Switching Products
- Downloads - WAN Switching Software
- Technical Support - Cisco Systems