May 12, 2004
Products Affected
|
Product |
Comments |
|---|---|
|
All FRSM Models |
In MGX running 1.2.20 and 1.2.21 software |
|
All CESM Models |
In MGX running 1.2.20 and 1.2.21 software |
|
All AUSM Models |
In MGX running 1.2.20 and 1.2.21 software |
Problem Description
Wrong connections go into A-Bit alarm at remote end.
This problem does not occur with the MGX-VISM or MGX-VISM-PR cards.
Background
When the prot resync mechanism gets triggered on an MGX running 1.2.20 or 1.2.21, the status of the wrong port is sent by the Service Module.
The net effect is that wrong interfaces programmed on the PXM1 get the port status from the service module. When a trigger event happens, the PXM1 sends A-Bit updates to the other end of the connections, and the wrong set of connections are put into alarm.
All data traffic on impacted ports stops. For a port to be impacted, there are two necessary conditions:
-
On the same SM, there must be another port whose ID is exactly half of the port that is being impacted
-
The state of this second port must be different than the state of the port being impacted. Example:
For port #16 to be impacted, port 8 must exist (on the same SM) and the state of port#8 should be different than the state of port #16.
Once the above conditions are met, the following set of events must occur for the bug to surface:
-
A switchcc, softswitch or port resync (port resync is a background task and happens every few hours). This will plant the problem but the data traffic will not be stopped at this point.
-
A network event, such as a CPE line/port bounce, or any other event that will prompt the PXM to send A-bit updates toward the network has to happen. This will trigger the outage on all PVCs attached to the problem port.
Problem Symptoms
Connections show A-Bit alarms even though remote end is not in alarm. The result is that the attached Frame Relay CPE shuts down the connections that are incorrectly showing A-Bit alarms and traffic stops passing.
mgxnod1.1.7.PXM.a > dspcons -slot 1
This End Node Name Other End Status
1.1.0.40 mgxnod1 1.9.0.23 OK
1.1.0.41 mgxnod1 3.19.0.23 OK
1.1.0.42 mgxnod1 3.6.0.23 FAILED <====================
1.2.0.34 mgxnod1 7.1.11.95 OK
Workaround/Solution
WorkAround:
None.
Solution:
-
Upgrade software to 1.3.00 or later 1.3 release or 1.2.22 or later 1.2 release.
-
Downgrade MGX software to a version earlier than 1.2.20.
Recovery:
Run the following command under shellConn of the FRSM card. Run this every time this problem is reported.
The command is send_port_traps .
send_port_traps function takes 4 parameters.
Parameter 1: Port Number This value is zero-based. ie For value of 50 in dspparifs and dspports , we need to pass 49 (ie, 50-1)
Parameter 2: Trap Number On FRSM-2CT3, FRSM-2T3E3 and FRSM-HS2/B card use 50381. This is fixed!
Parameter 3: Line Number The line number on which the port is added.
Parameter 4: PortDs0ConfigBitMap. This number of ds0 added on this port.
Parameter 1,3, and 4, i.e. Port No, Line num and PortDs0ConfigBitMap can be obtained from the dspport output.
For example, on port 50:
mgxnod1.1.5.VHS2CT3.a > dspport 50
SlotNum 5
PortLineNum 50 <--- Line Number (Parameter 3)
PortNum 50 <--- Port Number (Parameter 1)
PortRowStatus Add
PortDs0Speed 64k
PortDs0ConfigBitMap(1stDS0) 0xffffff(1) <--- (Parameter 4)
PortEqueueServiceRatio n/a
PortFlagsBetweenFrames 0
PortSpeed 1536 kbps
PortLmiSigConfMethod Manual
SignallingProtocolType AnnexDUNI
AsynchronousMsgs UPD_UFS disabled
T391LineIntegrityTimer 10 sec
T392PollingVerificationTimer 15 sec
N391FullStatusPollingCounter 6
N392ErrorThreshold 3
N393MonitoredEventCount 4
EnhancedLmi Off
PortState Active
PortSignallingState No Signalling Failure
CLLMEnableStatus Disable
So the command turns out to be:
send_port_traps 49,50381,50,0xffffff
Thus, for the above example, you need to call the function from shellConn with following parameter:
mgxnod1.1.5.VHS2CT3.a > shellConn
mgxnod1.1.5.VHS2CT3.a > send_port_traps 49,50381,50,0xffffff
send_port_traps 49,50381,50,0xffffff
value = 0 = 0x0
Parameter1 49 (ie, 50-1 .. because its zero based.)
Parameter2 50381 (Port up trap.)
Parameter3 50 (line num)
Parameter4 0xffffff (as shown in dspport output.)
Note that replacing the cards will not resolve this problem.
DDTS
To follow the bug ID link below and see detailed bug information, you must be a registered user and you must be logged in.
|
DDTS |
Description |
|---|---|
|
CSCee20455 (registered customers only) |
port resync on pop1 updates wrong port ids |