Revised November 08, 2004
October 26, 2004
Products Affected
-
GSR - 4OC12X/ATM-IR-SC
-
GSR - 4OC12X/ATM-IR-SC=
-
GSR - 4OC12X/ATM-MM-SC
-
GSR - 4OC12X/ATM-MM-SC=
Problem Description
When field diagnostic images earlier than Cisco IOS® Software Release 12.0(27)S are used on an Engine3 based OC12 ATM line card for the Cisco 12000 product family, diagnostics will indicate in the "error-log" that some tests fail.
Background
Field diagnostics images 12.0(25)S & 12.0(26) test for components that are not present on 4OC12X/ATM line cards and incorrectly report these tests as failing.
Example error log with invalid failures:
Router#diag 4 verbose source flash disk0:c12k-fdiagsbflc-mz.120-25.S1d Running DIAG config check Fabric Download for Field Diags chosen: If timeout occurs, try 'mbus' option. Verbose mode: Test progress and errors will be displayed Runnning Diags will halt ALL activity on the requested slot. [confirm] Launching a Field Diagnostic for slot 4 FD 4> ***************************************************** FD 4> GSR Field Diagnostics V6.12 FD 4> Compiled by award on Wed Mar 12 13:56:08 PST 2003 FD 4> view: award-conn_isp.Field_Diag_Release FD 4> ***************************************************** Executing all diagnostic tests in slot 4 (total/indiv. timeout set to 3000/600 sec.) FD 4> BFR_CARD_TYPE_OC12_4P_ATM_E48 testing...
...The following failing components show failing and are not present. ...
FD 4> SMB Device IOB FPGA failed to ack address FD 4> SMB Device MICKEY FPGA failed to ack address FD 4> SMB Device SAF0 FPGA failed to ack address FD 4> SMB Device SAF1 FPGA failed to ack address FD 4> IOB FPGA, SMB Protocol error FD 4> MICKEY FPGA, SMB Protocol error FD 4> SAF0 FPGA, SMB Protocol error FD 4> SAF1 FPGA, SMB Protocol error FDIAG_STAT_DONE_INIT_FAIL(4) test_num 70, error_code 1 FD 4> Changed current_status to FDIAG_STAT_IDLE Field Diagnostic: ****TEST INITIALIZATION FAILURE**** slot 4: first test failed: 70, Pinnacle PLIM read temperature, error 1 Field Diag eeprom values: run 1 fail mode 2 (TEST INITIALIZATION FAILURE) slot 4 last test failed was 70, error code 1 Shutting down diags in slot 4
Problem Symptoms
After running diagnostics on a 4OC12X/ATM line card some tests show as failing in the error log.
This happens only on Engine3 OC12 ATM line cards running Field Diagnostics version earlier than Cisco IOS Software Release 12.0(27)S.
Workaround/Solution
Use field diagnostics version 12.0(27)S or later with 4OC12X/ATM line cards. The 27S field diagnostics image will function properly and can be used with IOS releases earlier than version 12.0(27)S.
DDTS
To follow the bug ID link below and see detailed bug information, you must be a registered user and you must be logged in.
|
DDTS |
Description |
|---|---|
|
CSCeg05094 (registered customers only) |
Field Diags below 12.0(27)S on 4*OC12 ATM ISE LC fails |
For More Information
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
Receive Email Notification For New Field Notices
Product Alert Tool - Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.